Operating instructions
8
Daikin RoCon HP
Daikin Control
008.1420844 – 05/2014
3 x Operation
Exit button
This button can be used to jump back to the previous display
within a menu display or a function / input can be interrupted.
This button can also be used to call up the special level
(see section 3.5).
Action Result
Brief actuation.
Jump back to the previous display or pre-
vious level or
Cancellation of a special function or an
a
ctive temporary timer programme.
Press for more
than 5 s.
Special level is called up.
Tab. 3-4 Functions of the exit button
3.3 Operating concept
The operating concept for controlling the RoCon HP is structured
in such a way that the frequently required setting facilities are ac-
cessible quickly and directly at the ma
in function level (selection
using the rotary switch) and that the less frequently required
setting facilities are arranged at a lower parameter level.
1
2
3
45
6
7
8
9
1 Operating Mode (section 3.4.2)
2 Set Temp Day (section 3.4.3)
3 Set Temp Night (section 3.4.4)
4 DHW Set Temp (section 3.4.5)
5 DHW Install (section 3.4.6)
6 Time Program (section 3.4.7)
7 Configuration (section 3.4.8)
8 Remote Param (section 3.4.9)
9 Info (section 3.4.1)
Fig. 3-3 Illustration of main function level (rotary switch position)
Certain functions and parameters are restricted by access au-
thorisation and can only be adjusted by the heating expert
(see section 3.6.1).
In normal operating mode the rotary switch should be in
position
.
After switching on and successful initialisation, the display
automatically shows the standard display with rotary switch
position .
In the first commissioning, the setting for language selection is
displayed first.
Select the language using the rotary switch.
Confirm the changes with a brief push of the rotary switch.
Adaptation to the special installation configuration is
carried out in the rotary switch position "Configu-
ration"
(see section 3.4.8).
When the system is switched on, it regulates fully automatically,
based
on the stipulations set in the Control RoCon HP, the
operation of the
room heating, room cooling and the
sanitary hot water generation.
Independent of the setting of the rotary switch, the
Daikin Altherma EHS(X/H) operates in accordance with
the operating mode set in the switch position "Oper
-
ating Mode" or which has been activated by a
special programme.
If the user enters a value manually, this setting remains active
until the user changes it or until the programme clock forces an-
other operating mode.
The operating mode can be affected by additional functions such
as:
Weather-controlled flow temperature regulation
Switching time program
Setting the temperature ta
rget value
Setting at the room station
EXT signal (external operating mode switching)
–Quite Mode
Interlink fct
SMART GRID - Signal
EVU (reduced cost tariff) - Signal
Screed function
–Air Purge
Manual Operation
Button block
The operating panel on the RoCon HP can be blocked to prevent
inadvertent actuation (see fig. 3-4).
Unlocking can be carried out in the same way.
The prerequisite for this function is that, in the level "Setup", the
parameter [Keylock Function] is set to "On" (see chapter 5.2.1
tab. 5-1).
Keylock Function
On
Keylock Function
Keylock Function
Off
Fig. 3-4 Activating and deactivating the button block