b Booster 0 0 0 Not applicable
C Step-by-step modulation 1 1 1 0= step-by-step modulation off during CH operation
1= step-by-step modulation on during CH operation
2= Power control by Open Therm room thermostat
enabled
C Minimum rpm CH 30 30 30 Setting reach 20 to 50%
c. Minimum capacity modulating CH pump 40 40 40 Setting reach 15 to set value par. 3.
D Minimum rpm hot water 25 25 25 Setting reach 20 to 50%
E Min. leaving water temperature at OT
(OpenTherm) or RF thermostat
40 40 40 Setting reach 10°C to 60°C
E . Reaction OT and RF room thermostat 1 1 1 0= do not respond to hot water request if requested
temperature is lower than the set value par. E
1= respond to hot water request with minimum leaving
water temperature limited to set value par. E
2= respond to hot water request with maximum leaving
water temperature (on/off function)
F Start rpm CH 70 60 50 Settings reach 40 to 99% of the set maximum rpm
F . Minimum start rpm hot water 70 60 50 Settings reach 40 to 99% of the set maximum rpm
h
Max. rpm fan 50 50 50 Setting reach 40 to 50 (40=4000 rpm, 50=5000 rpm).
Please note: Factory setting, rpm may deviate
L Legionella protection 0 0 0 Not applicable (only for boilers with external DHW tank)
N Regulated temperature during boiler
operation (Ta)
80 80 80 Setting reach 60°C to 90°C
n. Hot water temperature at Comfort/Eco 0 0 0 Setting reach 0 or 40°C to 60°C
0 = reheating temperature is equal to hot water
temperature
O. Wait time CH request response 0 0 0 Settings reach 0 – 15 minutes
O Waiting time CH operation after hot water
operation
0 0 0 Settings reach 0 to 15 minutes
o. Number of eco days
3 3 3 Setting reach 0,1 to 10
0 = Comfort function controllable by Open Therm room
thermostat
1 – 10 number of eco days
P Anti-recycling time during CH operation 5 5 5 Minimum switch off time on boiler water temperature
Can be set to 0 to 15 minutes
P. Reference value hot water 24 30 36 24 = EKOMBG22ABV1
30 = EKOMBG28ABV1
36 = EKOMBG33ABV1
q Summer mode 0 0 0 0 = Summer mode deactivated
1 = Summer mode to be activated by button
(code in display : Su)
2 = Summer mode to be activated by button
(code in display : So)
3 = Summer mode to be activated by button
(code in display : Et)
r Heating curve coefficient 0 0 0 Not active