Daikin RKHBRD014ADV1 [15/24] Programming quiet mode or domestic water heating
![Daikin RKHBRD014ADV1 [15/24] Programming quiet mode or domestic water heating](/views2/1797485/page15/bgf.png)
RKHBRD011~016ADV1+Y1
Indoor unit for air to water heat pump system and options
4P403582-1 – 2015.04
Operation manual
14
Programming quiet mode or domestic water heating
Programming domestic water heating or quiet mode is carried out as
follows:
1 Press the button to enter the programming/consulting mode.
2 Select the operation mode you would like to program by means
of the and buttons.
The actual mode is blinking.
3 Press the button to confirm the selected mode.
4 Select the day you would like to program by means of the
and buttons.
The actual day is blinking.
5 Press the button to confirm the selected day.
6 Hold down the button for 5 seconds to the program the
detailed actions
The first programmed action of the selected day appears.
7 Use the button to select the action number you would like to
program or to modify.
8 Use the and buttons to set the correct action time.
9 Use the button to select or deselect as action.
10 Repeat steps 7 to 10 to program the other actions of the
selected mode.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
11 Press the button for 5 seconds to store the programmed
actions.
If the button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
By pressing the button several times, you return to previous
steps in this procedure and finally return to normal operation.
12 You automatically return to step 6, start again to program the
following day.
Consulting programmed actions
Consulting space heating, domestic water heating or quiet mode is
carried out as follows:
1 Press the button to enter the programming/consulting mode.
2 Select the operation mode you would like to consult by means of
the and buttons.
The actual mode is blinking.
3 Press the button to confirm the selected mode.
The actual day is blinking.
4 Select the day you would like to consult by means of the
and buttons.
The selected day is blinking.
5 Press the button to confirm the selected day.
The first programmed action of the selected day appears.
6 Use the and buttons to consult the other
programmed actions of that day.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the button several times, you return to previous
steps in this procedure and finally return to normal operation.
NOTE
Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the button.
NOTE
Returning to previous steps in this procedure is done
by pressing the button.
Содержание
- Operation manual p.1
- Indoor unit for air to water heat pump system and options p.1
- Scope of this manual p.2
- Operation manual p.2
- Introduction p.2
- General information p.2
- Domestic water heating operation p.3
- Space heating operation p.3
- Quick start up of the unit p.3
- Peration p.3
- Operation of the unit p.3
- Remote controller buttons and icons p.4
- Setting the clock p.5
- Space heating operation h p.6
- Space heating operation p.6
- Room temperature control p.6
- Leaving water temperature control p.6
- Domestic water heating operation w p.8
- Domestic water heating operation p.8
- Automatic storage p.8
- Manual storage p.9
- Defrost operation d p.10
- Defrost operation p.10
- Start up operation d p.10
- Start up operation p.10
- Reheat p.10
- Quiet mode operation s p.10
- Quiet mode operation p.10
- Other operation modes p.10
- Emergency operation p.10
- Disinfection operation p.10
- Temperature read out mode p.11
- Space heating p.11
- Simultaneous demand of space heating and domestic water heating p.11
- Schedule timer operation p.11
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer p.12
- Operation example schedule timer based on temperature set points p.12
- Operation example schedule timer based on on off instruction p.12
- Off on on p.12
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer if on instruction is active if off instruction is active this will have priority over the setback function at any time the off instruction will have the highest priority p.12
- Quiet mode p.13
- Programming and consulting the schedule timer p.13
- Domestic water heating p.13
- Programming space heating p.14
- Programming quiet mode or domestic water heating p.15
- Consulting programmed actions p.15
- Tips and tricks p.16
- Operating the remote alarm option p.16
- Operating the optional remote controller p.16
- Procedure p.17
- Field settings p.17
- Field settings table p.18
- Important information regarding the refrigerant used p.20
- Disposal requirements p.20
- Aintenance p.20
- Troubleshooting p.20
- Roubleshooting p.20
- Maintenance activities p.20
- Maintenance p.20
- Isposal requirements p.20
- P403582 1 p.24
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика