Daikin RKHBRD014ADV1 — руководство по эксплуатации для систем отопления и горячей воды [8/24]
![Daikin RKHBRD014ADY1 [8/24] Domestic water heating operation w](/views2/1797485/page8/bg8.png)
Operation manual
7
RKHBRD011~016ADV1+Y1
Indoor unit for air to water heat pump system and options
4P403582-1 – 2015.04
Domestic water heating operation ( )
For the domestic water heating mode, several operations are
possible:
• storage operation (either automatic or manually set)
• reheat operation
• disinfection operation
The purpose of each operation, and how the configuration is done, is
explained below.
Domestic water heating modes
Automatic storage
In this mode, the indoor unit will deliver hot water to the domestic hot
water tank based on the daily fixed pattern. This mode will continue
until the storage temperature set point is reached. During operation
of this mode, the icon will be blinking with 1 second intervals.
Automatic storage is the recommended domestic hot water mode. In
this mode, water heats up during the night (when space heating
requirements are lower) until the storage temperature set point is
reached. The heated water is stored in the domestic hot water tank at
a higher temperature so it can fulfil the domestic hot water
requirements throughout the day.
The storage temperature set point and the timing are field settings.
Refer to the chapter "Field settings" on page 16 for a detailed
description how to set one or more field settings.
■ [1-00] Status: defines whether the domestic water heating
(storage mode) during night is enabled (1) or not (0).
■ [1-01] Start time: time of the night at which the domestic water
should be heated.
■ [1-02] Status: defines whether the domestic water heating
(storage mode) during daytime is enabled (1) or not (0).
■ [1-03] Start time: time of the day at which the domestic water
should be heated.
■ [b-03] set point: storage temperature (see figure "Domestic
water heating modes" on page 7) only valid if [b-02]=0.
■ [b-02] Status: defines whether the weather dependent domestic
water heating is turned ON (1) or OFF (0).
If enabled, the storage set point will be set weather dependent.
In case of a higher ambient temperature (e.g. during summer-
time), temperature of supply water to the domestic hot water
tank will be higher too, so that storage temperature set point can
be set lower in order to keep the overall equivalent hot water
amount the same during the whole year. Therefor it is
recommended to use this function.
■ [b-04] Automatic maximum domestic hot water storage
temperature: default = 70°C.
NOTE
Any domestic water heating operation is impossible
when the domestic hot water tank is not installed.
A Storage operation (if activated)
B Reheat operation (if activated)
C Disinfection operation (if activated)
Field settings
D Disinfection operation temperature [5-00] (e.g. 70°C)
E Hot water storage temperature [b-03] (e.g. 60°C)
F Reheat maximum water temperature [b-01] (e.g. 45°C)
G Reheat minimum water temperature [b-00] (e.g. 35°C)
t Time
T Domestic hot water tank temperature
AB C
D
E
F
G
T
t
[5-01]
NOTE
Remark that the icon will only be blinking during
effective automatic storage operation. Presence of the
permanently lit icon does not mean that automatic
storage is enabled, but only means that reheat is
enabled.
During operation it is always possible to cancel the
operation by pushing the button once.
Be aware that after pushing the button, it is possible
that the permanently lit icon still displays.
Be aware that despite the automatic storage is a
pre-programmed schedule timer, it is only active when the
schedule timer is enabled. This means that you have to
push the button and confirm that the is displayed to
make sure that the automatic storage will operate.
A Ambient temperature
T Domestic hot water storage temperature
NOTE
The ambient temperatures for weather dependent
domestic water heating (see figure) are fixed and can
not be changed.
T
A
[b-04]
55°C
15°C25°C
Содержание
- Operation manual p.1
- Indoor unit for air to water heat pump system and options p.1
- Scope of this manual p.2
- Operation manual p.2
- Introduction p.2
- General information p.2
- Domestic water heating operation p.3
- Space heating operation p.3
- Quick start up of the unit p.3
- Peration p.3
- Operation of the unit p.3
- Remote controller buttons and icons p.4
- Setting the clock p.5
- Space heating operation h p.6
- Space heating operation p.6
- Room temperature control p.6
- Leaving water temperature control p.6
- Domestic water heating operation w p.8
- Domestic water heating operation p.8
- Automatic storage p.8
- Manual storage p.9
- Defrost operation d p.10
- Defrost operation p.10
- Start up operation d p.10
- Start up operation p.10
- Reheat p.10
- Quiet mode operation s p.10
- Quiet mode operation p.10
- Other operation modes p.10
- Emergency operation p.10
- Disinfection operation p.10
- Temperature read out mode p.11
- Space heating p.11
- Simultaneous demand of space heating and domestic water heating p.11
- Schedule timer operation p.11
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer p.12
- Operation example schedule timer based on temperature set points p.12
- Operation example schedule timer based on on off instruction p.12
- Off on on p.12
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer if on instruction is active if off instruction is active this will have priority over the setback function at any time the off instruction will have the highest priority p.12
- Quiet mode p.13
- Programming and consulting the schedule timer p.13
- Domestic water heating p.13
- Programming space heating p.14
- Programming quiet mode or domestic water heating p.15
- Consulting programmed actions p.15
- Tips and tricks p.16
- Operating the remote alarm option p.16
- Operating the optional remote controller p.16
- Procedure p.17
- Field settings p.17
- Field settings table p.18
- Important information regarding the refrigerant used p.20
- Disposal requirements p.20
- Aintenance p.20
- Troubleshooting p.20
- Roubleshooting p.20
- Maintenance activities p.20
- Maintenance p.20
- Isposal requirements p.20
- P403582 1 p.24
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Изучите различные режимы работы для систем отопления и горячего водоснабжения. Узнайте, как настроить автоматическое хранение и другие функции для оптимизации работы.