Daikin EHYKOMB33AA2A [103/108] Chyhbh 4p471775 1 2016 2

Daikin EHYKOMB33AA3 [103/108] Chyhbh 4p471775 1 2016 2
3/6
Breadcrumb Field code Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
Setting name
A.2.2.B [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.C [D-0A] R/O
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
└─ Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1 R/W 0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
A.3.1.1.2.1 [9-01] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.1.2.2 [9-00] Temperature range Maximum temp (heating) R/W 37~80°C, step: 1°C
80°C
A.3.1.1.5 [8-05] R/W 0: No
1: Yes
A.3.1.1.6.1 [F-0B] Shut-off valve Thermo On/OFF R/W
0: No
1: Yes
A.3.1.1.7 [9-0B] R/W
0: Quick
1: Slow
└────────────────── Additional
A.3.1.2.1 R/W 0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
A.3.1.2.2.1 [9-05] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.2.2.2 [9-06] Temperature range Maximum temp (heating) R/W 37~80°C, step: 1°C
80°C
└─ Room thermostat
A.3.2.1.1 [3-07] Room temp. range Minimum temp (heating) R/W 12~18°C, step: A.3.2.4
12°C
A.3.2.1.2 [3-06] Room temp. range Maximum temp (heating) R/W 18~30°C, step: A.3.2.4
30°C
A.3.2.2 [2-0A] R/W -5~5°C, step: 0,5°C
0°C
A.3.2.3 [2-09] R/W -5~5°C, step: 0,5°C
0°C
A.3.2.4 R/W
0: 1°C
1: 0,5°C
└─ Operation range
A.3.3.1 [4-02] R/W 14~35°C, step: 1°C
25°C
└─ Domestic hot water (DHW)
└─ Type
A.4.1 [6-0D]
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
└─ Disinfection
A.4.4.1 [2-01] R/W
0: No
1: Yes
A.4.4.2 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
A.4.4.3 [2-02] R/W 0~23 hour, step: 1 hour
23
A.4.4.4 [2-03] R/W fixed value
60°C
A.4.4.5 [2-04] R/W 40~60 min, step: 5 min
40 min
└─ Maximum setpoint
A.4.5 [6-0E] R/W [E-06]=1
[E-07] 6: 40~75°C, step: 1°C, 75°C
[E-07] = 6: 40~60°C, step: 1°C, 60°C
[E-06]=0
40~65°C
,
ste
p
: 1°C
,
65°C
└─ SP mode
A.4.6 R/W
0: Fixed
1: Weather de
p
.
└─ Weather dependent curve
A.4.7 [0-0B] Weather-dependent curve DHW setpoint for high ambient temp. for DHW
WD curve.
R/W 35~[6-0E]°C, step: 1°C
55°C
A.4.7 [0-0C] Weather-dependent curve DHW setpoint for low ambient temp. for DHW
WD curve.
R/W 45~[6-0E]°C, step: 1°C
60°C
A.4.7 [0-0D] Weather-dependent curve High ambient temp. for DHW WD curve. R/W 10~25°C, step: 1°C
15°C
A.4.7 [0-0E] Weather-dependent curve Low ambient temp. for DHW WD curve. R/W -40~5°C, step: 1°C
-10°C
└─ Heat sources
└─ Boiler
A.5.2.2 [5-01] R/W -15~35°C, step: 1°C
5°C
└─ System operation
└─ Auto restart
A.6.1 [3-00] R/W 0: No
1: Yes
└─ Averaging time
A.6.4 [1-0A] R/W 0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Ext amb. sensor offset
A.6.5 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
└─ Savings mode
Equilibrium temp.
Disinfection
Operation day
Start time
Temperature target
Duration
Emitter type
LWT setpoint mode
Room temp. offset
Ext. room sensor offset
Room temp. step
Space heating OFF temp
External sensor
External gas meter
LWT setpoint mode
Modulated LWT
CHYHBH* 4P471775-1 - 2016.12