Daikin EHYKOMB33AA2A [96/108] Technical data

Превью страниц Страница 96 / 108
Daikin EHYKOMB33AA2 [96/108] Technical specifications gas boiler
15 Technical data
Installer reference guide
96
CHYHBH05+08AA + EHYKOMB33A
Daikin hybrid for multi heat pump – heat pump module
4P471761-1A – 2017.10
15.8 Technical specifications: Gas
boiler
15.8.1 General
EHYKOMB33AA*
Function Heating – Domestic hot
water
Heat pump module CHYHBH05
CHYHBH08
Device category C13, C33, C43, C53, C63,
C83, C93
Gas
Gas consumption (G20) 0.78~3.39m
3
/h
Gas consumption (G25) 0.90~3.93m
3
/h
Gas consumption (G31) 0.30~1.29m
3
/h
Nox class 5
Central heating
Thermal load (Hi) 7.6~27.0kW
Heating power space heating (80/60) 8.2~26.6kW
Efficiency space heating (net calorific
value 80/60)
98%
Efficiency space heating (net calorific
value 40/30 (30%))
107%
Operation range 15~80°C
Pressure drop See ESP curve in the
installer reference guide.
Domestic hot water (not applicable for Switzerland)
Heating power domestic hot water 7.6~32.7kW
Efficiency domestic hot water (net
calorific value)
105%
Operation range 40~65°C
Domestic hot water flow rate (setpoint
60°C)
9l/min
Domestic hot water flow rate (setpoint
40°C)
15l/min
Casing
EHYKOMB33AA*
Colour White – RAL9010
Material Pre-coated sheet metal
Dimensions
Packing (H×W×D) 820×490×270mm
Unit (H×W×D) 710×450×240mm
Machine net weight 36kg
Packed machine weight 37kg
Packing material Carton/PP (straps)
Packing material (weight) 1kg
Main components
Water side heat exchanger Aluminium
Space heating water circuit
Space heating piping connections Ø22mm
Piping material Cu
Safety valve See indoor unit manual
Manometer Yes
Drain/fill valve No
Shut‑off valves No
Air purge valve Yes
Maximum pressure space heating
circuit
3bar
Domestic hot water circuit (not applicable for Switzerland)
Domestic hot water piping connections Ø15mm
Piping material Cu
Gas connection Ø15mm
Flue gas/combustion air connection Concentric connection
Ø60/100mm
Electrical
Power supply voltage 230V
Power supply phase 1~
Power supply frequency 50Hz
IP class IP44
Maximum electrical power consumption 55W
Electrical power consumption (standby) 2W
15.8.2 Gas category and supply pressure
Country Gas category Default setting After conversion to G25 After conversion to G31
Germany II2ELL3P G20 (20mbar) G25 (25mbar) G31 (28~50mbar)
Belgium
1
I2E(s)3Pc,
I3P
G20 (20mbar) G25 (25mbar) G31 (30mbar)
France II2Esi3P G20 (20mbar) G25 (25mbar) G31 (30mbar)
Italy II2H3P G20 (20mbar) G31 (30mbar)
United Kingdom II2H3P G20 (20mbar) G31 (30~37mbar)
Spain II2H3P G20 (20mbar) G31 (30~37mbar)
Austria II2H3P G20 (20mbar) G31 (30~50mbar)
Bulgaria II2H3P G20 (20mbar) G31 (30mbar)
Czech Republic II2H3+,
II2H3P
G20 (20mbar) G31 (37mbar)
Croatia II2H3P G20 (20mbar) G31 (30mbar)
Hungary II2HS3P G25 (25mbar) G31 (30mbar)
Slovakia II2H3P G20 (20mbar) G31 (30~50mbar)
Slovenia II2H3P G20 (20mbar) G31 (37mbar)
(1)
Any modifications to the gas valve MUST be performed by a certified representative of the manufacturer. For more
information, contact your dealer.

Содержание

553