Daikin LRYEN10A7Y1 [41/140] About the units and options

Daikin LRYEN10A7Y1 [41/140] About the units and options
14 | About the units and options
Installer and user reference guide
41
LRYEN10A7Y1+LRNUN5A7Y1
CO₂ Conveni-Pack outdoor unit
4P605460-1 – 2020.08
14 About the units and options
In this chapter
14.1 Identification........................................................................................................................................................................... 41
14.1.1 Identification label: Outdoor unit .......................................................................................................................... 41
14.2 About the outdoor unit .......................................................................................................................................................... 42
14.2.1 Labels on outdoor unit........................................................................................................................................... 43
14.3 System layout.......................................................................................................................................................................... 46
14.4 Combining units and options.................................................................................................................................................. 47
14.4.1 Possible combinations of indoor units................................................................................................................... 47
14.4.2 Possible options for the outdoor unit.................................................................................................................... 48
14.5 Indoor unit constraints ........................................................................................................................................................... 48
14.5.1 Constraints for air conditioning ............................................................................................................................. 48
14.5.2 Constraints for refrigeration .................................................................................................................................. 49
14.1 Identification
NOTICE
When installing or servicing several units at the same time, make sure NOT to switch
the service panels between different models.
14.1.1 Identification label: Outdoor unit
Location
a b
a Outdoor unit
b Capacity up unit
Model identification
Outdoor unit: LRYEN10A7Y1
Code Explanation
Outdoor unit: LRYEN10A7Y1:
LR Product category:
L: Low temperature air conditioner
R: Outdoor unit
YE Heatpump + economizer
N Refrigerant: R744 (CO
2
)
10 Capacity indication in HP
A7 Major design category: European design
Y1 power supply (3~/50Hz/380~415V)