TC PI TC PI TC PI TC PI TC PI TC PI
DB WB
KW KW KW KW KW KW KW KW KW KW KW KW
-14.7 -15.0 82.2 22.0 82.2 23.2 82.2 24.5 82.2 25.1 82.2 25.7 82.2 27.0
-12.6 -13.0 87.2 23.2 87.2 24.4 87.2 25.6 87.2 26.2 87.2 26.8 87.2 28.0
-10.5 -11.0 92.4 24.4 92.4 25.5 92.4 26.6 92.4 27.2 92.4 27.7 92.4 28.8
-9.5 -10.0 95.7 24.9 95.7 26.0 95.7 27.0 95.7 27.6 95.7 28.2 95.7 29.3
-8.5 -9.1 98.4 25.3 98.4 26.4 98.4 27.4 98.4 28.0 98.4 28.5 98.4 29.6
-7.0 -7.6 102.5 26.0 102.5 27.0 102.5 28.1 102.5 28.7 102.5 29.0 102.5 30.1
-5.0 -5.6 107.8 26.8 107.8 27.8 107.8 28.7 107.8 29.3 107.8 29.8 107.8 30.7
-3.0 -3.7 112.8 27.6 112.8 28.4 112.8 29.5 112.8 30.0 112.8 30.3 112.8 31.4
0.0 -0.7 120.3 28.6 120.3 29.5 120.3 30.3 120.3 30.8 120.3 31.2 120.3 32.0
3.0 2.2 127.2 29.5 127.2 30.3 127.2 31.1 127.2 31.4 127.2 31.9 127.2 32.8
5.0 4.1 132.4 30.0 132.4 30.8 132.4 31.6 132.4 31.9 132.4 32.5 132.4 33.1
7.0 6.0 137.5 30.5 137.5 31.3 137.5 31.9 137.5 32.4 137.5 32.8 137.5 33.6
9.0 7.9 142.5 30.8 142.5 31.6 142.5 32.4 142.5 32.8 142.5 33.1 142.5 33.9
11.0 9.8 147.9 31.4 147.9 31.9 147.9 32.8 147.9 33.1 147.9 33.6 147.9 34.2
13.0 11.8 152.7 31.6 152.7 32.4 152.7 33.1 152.7 33.6 152.7 33.9 152.7 34.5
15.0 13.7 157.5 32.1 157.3 32.7 157.3 33.4 157.3 33.9 157.3 34.2 155.5 34.3
19.0 14.2 157.5 32.5 157.3 33.1 157.3 33.7 157.3 34.2 157.3 34.5 155.5 33.6
21.0 15.0 157.5 32.9 157.3 33.5 157.3 34.0 157.3 34.4 157.3 34.2 155.5 32.9
-14.7 -15.0 82.2 23.7 82.2 24.8 82.2 26.0 82.2 26.6 82.2 27.1 82.2 28.3
-12.6 -13.0 87.2 24.8 87.2 25.9 87.2 27.0 87.2 27.6 87.2 28.1 87.2 29.3
-10.5 -11.0 92.4 25.9 92.4 26.9 92.4 27.9 92.4 28.5 92.4 29.0 92.4 30.1
-9.5 -10.0 95.7 26.4 95.7 27.4 95.7 28.4 95.7 28.8 95.7 29.3 95.7 30.4
-8.5 -9.1 98.4 26.8 98.4 27.7 98.4 28.7 98.4 29.3 98.4 29.8 98.4 30.7
-7.0 -7.6 102.5 27.4 102.5 28.4 102.5 29.3 102.5 29.8 102.5 30.1 102.5 31.2
-5.0 -5.6 107.8 28.1 107.8 29.0 107.8 30.0 107.8 30.4 107.8 30.9 107.8 31.7
-3.0 -3.7 112.8 28.9 112.8 29.7 112.8 30.6 112.8 30.9 112.8 31.4 112.8 32.3
0.0 -0.7 120.3 29.8 120.3 30.6 120.3 31.4 120.3 31.7 120.3 32.2 120.3 32.6
3.0 2.2 127.2 30.6 127.2 31.4 127.2 32.2 127.2 32.5 127.2 32.8 127.2 33.7
5.0 4.1 132.4 31.1 132.4 31.7 132.4 32.5 132.4 32.8 132.4 33.3 132.4 34.0
7.0 6.0 137.5 31.4 137.5 32.2 137.5 33.0 137.5 33.3 137.5 33.6 137.5 34.5
9.0 7.9 142.5 31.9 142.5 32.5 142.5 33.3 142.5 33.6 142.5 33.9 142.8 34.7
11.0 9.8 147.9 32.2 147.9 33.0 147.9 33.6 147.9 33.9 147.9 34.2 143.8 33.8
13.0 11.8 152.7 32.7 152.7 33.3 152.7 33.9 152.7 34.2 152.7 34.7 143.8 32.6
15.0 13.7 157.3 33.0 157.3 33.6 157.3 34.2 157.3 34.5 154.3 34.0 143.8 31.2
19.0 14.2 157.3 33.5 157.3 34.0 157.3 34.4 157.3 34.1 154.3 33.4 143.8 30.6
21.0 15.0 157.3 33.9 157.3 34.1 157.3 34.2 157.3 33.7 154.3 32.3 143.8 30.1
-14.7 -15.0 82.2 25.3 82.2 26.4 82.2 27.4 82.2 28.0 82.2 28.6 82.2 29.6
-12.6 -13.0 87.2 26.4 87.2 27.4 87.2 28.5 87.2 29.1 87.2 29.4 87.2 30.5
-10.5 -11.0 92.4 27.4 92.4 28.2 92.4 29.3 92.4 29.8 92.4 30.2 92.4 31.2
-9.5 -10.0 95.7 27.8 95.7 28.8 95.7 29.6 95.7 30.1 95.7 30.7 95.7 31.5
-8.5 -9.1 98.4 28.2 98.4 29.1 98.4 30.1 98.4 30.4 98.4 30.9 98.4 31.8
-7.0 -7.6 102.5 28.7 102.5 29.6 102.5 30.4 102.5 30.9 102.5 31.4 102.5 32.3
-5.0 -5.6 107.8 29.5 107.8 30.3 107.8 31.2 107.8 31.5 107.8 32.0 107.8 32.8
-3.0 -3.7 112.8 30.1 112.8 30.9 112.8 31.7 112.8 32.0 112.8 32.6 112.8 33.2
0.0 -0.7 120.3 30.9 120.3 31.7 120.3 32.5 120.3 32.8 120.3 33.1 120.3 34.0
3.0 2.2 127.2 31.7 127.2 32.5 127.2 33.1 127.2 33.4 127.2 33.9 127.2 34.5
5.0 4.1 132.4 32.2 132.4 32.8 132.4 33.4 132.4 33.9 132.4 34.2 131.8 34.5
AV44NMVERA heating mode
capacity
factor
outdoor temp.
indoor temp. (DB)
16.0 18.0 20.0 21.0 22.0 24.0
130
120
110
373