Citizen CT-S751 [107/565] Esc w xl xh yl yh dxl dxh dyl dyh

Citizen CT-S2000 [107/565] Esc w xl xh yl yh dxl dxh dyl dyh
Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
CT-S751
CT-S4500
- 106 -
ESC W xL xH yL yH dxL dxH dyL dyH
[Function] Defining the print area in PAGE MODE
[Code] <1B>H<57>H<xL><xH><yL><yH><dxL><dxH><dyL><dyH>
[Range] 0xL, xH, yL, yH, dxL, dxH, dyL, dyH 255
except for dxL=dxH=0 or dyL=dyH=0
[Outline] [The specification which is common to the model]
Defines the location and size of the print area.
Horizontal start point = [(xL+xH×256)×basic calculation pitch(x)] inches
Vertical start point = [(yL+yH×256)×basic calculation pitch(y)] inches
Horizontal length = [(dxL+dxH×256)×basic calculation pitch(x)] inches
Vertical length = [(dyL+dyH×256)×basic calculation pitch(y)] inches
[Caution] [The specification which is common to the model]
When STANDARD MODE is selected, this command only executes the internal flagging of the
printer without affecting the printing in STANDARD MODE.
If the horizontal start point or vertical start point is out of the printable area, this command is canceled and the
next data is handled as normal data.
If the horizontal length or vertical length is 0, this command is canceled and the next data is handled as
normal data.
The character mapping position will be the start point specified by ESC T in the print area.
If the horizontal start point + horizontal length is greater than the horizontal printable area, the horizontal
printable area horizontal start point is taken as the horizontal length.
If the vertical start point + vertical length is greater than the vertical printable area, the vertical printable area
vertical start point is taken as the vertical length.
The basic calculation pitch is defined by GS P. Once defined, the print area is not changed if the basic
calculation pitch is changed by GS P.
Fractions resulting from calculations are corrected with the minimum pitch of the mechanism, and the
remainder is omitted.
The horizontal start point and horizontal length are calculated with the basic calculation pitch (x). The vertical
start point and vertical length are calculated with the basic calculation pitch (y).
The figure below illustrates the print area, where X = horizontal start point, Y = vertical start point, Dx =
horizontal length, and Dy = vertical length.
XY
Print Area
X+Dx-1Y+Dy-1
Paper feed direction

Содержание

Скачать