Citizen CT-S751 [265/565] Ct s300

Citizen CT-E651 [265/565] Ct s300
Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
CT-S751
CT-S4500
- 264 -
CT-S300
• a=202: Controls input buffer full Busy with the value selected by
(nL+nH×256) and controls Busy with output/cancel timing
(remaining capacity).
(nL+nH×256)
When Input Buffer
Capacity 4K Bytes (Large)
is Set
Output
Cancel
Output
Cancel
1 (Default)
16
26
128
256
2
16
40
128
512
3
30
50
72
256
4
30
60
72
512
• XON/XOFF is also output by the establishment of conditions.
• Ignores the data received when input buffer idle capacity is 0.
a=220: Sets the maximum width of black mark by the amount selected by
(nL+nH×256)
1≤(nL+nH×256)≤32767
Unit: 1 dot
Initial value: 40 dots
a=221: Sets the maximum length of black mark page with the value
selected by (nL+nH×256).
1≤(nL+nH×256)≤32767
Unit: 1 dot
Initial value: 2360 dots
a=222: Head margin set by the value selected by (nL+nH×256).
1≤(nL+nH×256)≤32767
Unit: 168dot
Initial value: 0dot
a=223: Sets black mark bottom margin with the amount selected by
(nL+nH×256).
1≤(nL+nH×256)255
Unit: 1 dot
Initial value: 34 dots
a=224: Sets cut distance with the value selected by (nL+nH×256).
1≤(nL+nH×256)255
Unit: 1 dot
Initial value: 232 dots
a=225: Sets head distance with the value selected by (nL+nH×256).
1≤(nL+nH×256)255
Unit: 1 dot
Initial value: 56 dots