GS C ; n1 ; n2 ; n3 ; n4 ; n5 ;
[Function] Setting the numbering counter mode (B)
[Code] <1D>H<43>H<3B>H<n1><3B>H<n2><3B>H<n3><3B>H<n4><3B>H<n5><3B>H
<n1>, <n2>, <n3>, <n4>, <n5> are character codes.
[Range] 0n1, n2, n565535
0n3, n4255
[Outline] [The specification which is common to the model]
This command sets the numbering (serial number counter) mode and a counter value.
n1: First value of ounter range
n2: Last vale of counter range
n3: Counter step value
n4: Identical counter print count
n5: Counter start value
n1<n2: Count-up system
n1>n2: Count-down system
n1=n2 or n3= 0 or n4=0 : Counter stop
[Caution] [The specification which is common to the model]
If the n5 counter start value is beyond the counter range specified with n1 and n2, it is assumed to
be n1=n5.
If each value of n1 through n5 contains the character code other than 0 through 9, the printer will invalidate
the data up to that parameter and handle the subsequent data as normal data.
[Default] n1=1, n2=65535, n3=1, n4=1, n5=1
[See Also] GS C 0, GS C 1, GS C 2, GS c