Citizen CT-S751 [416/565] Gs k pl ph cn fn m d1 dk

Citizen CT-S281 [416/565] Gs k pl ph cn fn m d1 dk
Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
CT-S751
CT-S4500
- 415 -
fn=70: Function 70 Setting Options for PDF417
GS ( k pL pH cn fn m
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m>
[Range] (pL+pH×256)=3 (pL=3, pH=0)
cn=48
fn=70
m=0, 1
[Outline] [The specification which depend on the model]
Specifies or clears the PDF417 option.
m
0
1
[Caution] When cleared with m=0, standard processing for PDF417 is conducted thereafter.
[Default] m=0
fn=80: Function 80 Storing received data to 2D code data storage area
GS ( k pL pH cn fn m d1...dk
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m><d1dk>
[Range] 4(pL+pH×256)65535(0pL255, 0pH255)
cn=48
fn=80
m=48
0d255
k=(pL+pH×256)-3
[Outline] [The specification which is common to the model]
Stores PDF417 2-dimensional code data (d1…dk) to 2-dimensional code data storage
area.
Processes [(pL+pH×256)-3] of d1 and thereafter as 2-dimensional code data.
[Sample Program]
[Print Results]
Refer to Sample Program and Print Results for fn=81: Function181.