Citizen CT-S751 [400/565] Gs e pl ph fn a

Citizen CT-E351 [400/565] Gs e pl ph fn a
Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
CT-S751
CT-S4500
- 399 -
fn=12: Function 12 Sending the Set Communication Conditions
GS ( E pL pH fn a
[Code] <1D>H<28>H<45>H<pL><pH><fn><a>
[Range] (pL+pH×256)=2 (pL=2, pH=0)
fn=12
1a4 (Does not send in other than specified range)
[Outline] [The specification which is common to the model]
Sends communication conditions of serial interface specified by a.
No. of Data
Header
1
ID
1
Kind of communication conditions (a)
1
Separation number
1
Set value
1 to 6
NULL
1
Set value
a=1: At specification of baud rate
Baud Rate
d1
d2
d3
d4
D5
d6
1200
49(1)
50(2)
48(0)
48(0)
-
-
2400
50(2)
52(4)
48(0)
48(0)
-
-
4800
52(4)
56(8)
48(0)
48(0)
-
-
9600
57(9)
54(6)
48(0)
48(0)
-
-
19200
49(1)
57(9)
50(2)
48(0)
48(0)
-
38400
51(3)
56(8)
52(4)
48(0)
48(0)
-
●57600
53(5)
55(7)
54(6)
48(0)
48(0)
-
115200
49(1)
49(1)
53(5)
50(2)
48(0)
48(0)
---support by CT-S280/CT-S281/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/ CT-E651/CT-S751/CT-S4500
---support by CT-S280/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-P29x series/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/ CT-E651/CT-S751/CT-S4500
(CT-P29x series does not support 115200bps)
a=2: At specification of parity
d1
Parity Setting
48
No parity
49
Odd parity
50
Even parity
a=3: At specification of flow control
d1
Flow Control
48
DTR/DSR
49
XON/XOFF
a=4: At specification of data length
d1
Setting Data Length
48
7-bit length
49
8-bit length

Содержание

Скачать