Graco Reactor 2 E-30 FP2110 [56/78] Shutdown

Graco Reactor 2 E-30 FP2110 [56/78] Shutdown
Spraying
Shutdown Shutdown
Shutdown
NOTICE NOTICE
NOTICE
Propersystemsetup,startup,andshutdown
proceduresarecriticaltoelectricalequipment
reliability.Thefollowingproceduresensuresteady
voltage.Failuretofollowtheseprocedureswill
causevoltage󰘱uctuationsthatcandamage
electricalequipmentandvoidthewarranty.
1.Presstostopthepumps.
2.Turnoffallheatzones.
3.Relievepressure.See
PressureReliefProcedure,page60.
4.PresstoparktheComponentAPump.The
parkoperationiscompletewhengreendotgoes
out.Verifytheparkoperationiscompletebefore
movingtonextstep.
5.Presstodeactivatethesystem.
6.Turnofftheaircompressor,airdryer,and
breathingair.
7.TurnmainpowerswitchOFF.
Topreventelectricshockdonotremoveany
coversoropentheelectricalenclosuredoor
whilethepowerisON.
8.Closeall󰘱uidsupplyvalves.
56 333023T