Al-Ko HWF 1004 [12/120] Checking the inlet pressure

Al-Ko HWF 1004 [12/120] Checking the inlet pressure
Checking the inlet pressure
Prior to installing the filter, check the two
seals (21) on the filter and the seal (16) for
damage, if necessary renew.
Unplug the electric cable from the socket.
Open the pressure line and drain the water
off until the pump is completely empty.
The seal (25) must be correctly inserted in
the seal seat on the pump head (see Detail
in Fig. C). If necessary lightly grease the
seal with non-acidic fat.
Check the inlet pressure at the diaphragm
(5).
The pressure should be approx. 1.5 bar.
Correct the pressure if needed.
Install the filter, screw on filter cover and
tighten firmly with the hand using filter span-
ner.
Put the domestic water system into operation
as set out in the instructions.
Disposal
Removing and mounting of non-return
valve, cleaning
RL 2002/96 EG
Do not dispose of worn-out units
through the household garbage!
The appliance, its packaging and
accessories are all produced
from recyclable materials and
must be disposed of accordingly.
Remove the filter (see Section "cleaning the
filter").
Unscrew the non-return valve (23) and clean
it under flowing water.
Renew seal (24) if necessary.
Install the non-return valve.
Install the filter and filter cover.
Frost protection
Your domestic water system is susceptible to low
temperatures. Make sure to empty the device of
residual liquid (hoses, pump and reservoir) and
store it so that it is protected from frost.
Empty the suction and pressure hoses.
Remove the draining screws (9) and (12)
drain all water from the pump chamber. The
water contained in the reservoir will be
pressed out by the air bellows.
Replace the draining screws and store the
device so that it is protected from frost.
Setting the pressure switch
The cut-in and cut-out pressures at which the
sys- tem starts and stops operating have been
set in the factory (see technical data). However,
if desired, you can adjust the setting as desired
at the pressure switch (10).
Settings on the pushbutton switch and on
the electrical part of the house water plant
may be performed only by the responsible
customer service.
Translation of original user instructions GB 4

Содержание

Скачать
Случайные обсуждения

Ответы 0

Какой объём груши в ней
10 месяцев назад

Ответы 0

Регулировка давления.
6 лет назад

Ответы 0

Здравствуйте, нужна помощь, у меня AL-ko HWF1400 INOX подскажите для чего нужны четыре шурупа на крышке №462837 ? и должны ли быть они вообще там ? + они абсолютна не крепятся в сомой крышке где они находились, нет резьбы, они попросту вставлены и не закреплены.Думаю моя причина поломки была в том что один из этих шурупов выскочил и упал вниз крышки №462823 перегородив проход в стальном шланге который крепится именно к этой крышке, из за чего насос не мог набить нужное давления что бы выключиться . P.s в самой инструкции, на рисунке невидно этих шурупов на крышке №462837 видно всего два шурупа которые крепят деталь №462838 у меня же с этими двумя ещё 4ре, получается 6 шурупов. Расположение 4х шурупов находится, если обратить внимание на рисунок детали №462837 под отверстием для входа входы есть крестообразное пересечение в центре, и 4ре круглых углубления . В каждом из этих углублений находился один из 4х шурупов. Нужны ли они там и зачем, если да ?
9 лет назад