RCF VSA 1250 W MKII [14/18] Equalizer setting window

RCF VSA 1250 W MKII [14/18] Equalizer setting window
16
ENGLISH
EQUALIZER SETTING WINDOW
Click EQ to open and edit the equalizer window (relative to the three custom equalizations),
which includes both Gain and Delay settings as well.
First, in the Active Equalizer option menu, choose one of the three custom equalizations
CUSTOM 1 – 2 – 3 to edit.
It is possible to set up to eight independent filters (Filter 1, 2, 3, 4, 5, 6, 7, 8).
Enabled: click the checkbox to toggle each filter.
Move the mouse on its white background (making it green) to highlight a filter (if present) on
the EQ graph.
Type:
- DISABLED: the filter is disabled (by-pass).
- PEQ: parametric equalizer that allows to adjust the level at the settable centre frequency and
specify the Q factor (the adjusted level can be widened or narrowed).
- SHELVING HIGH: increase or decrease the level of all frequencies above the selected
frequency by the specified amount.
- SHELVING LOW: increase or decrease the level of all frequencies below the selected frequency
by the specified amount.
- The BUTTERWORTH, LINKWITZ-RILEY, BESSEL options are only available for the filters
no.1 (‘high-pass’) and no.8 (‘low-pass’).
Slope: filter slope setting (dB / oct).
Q: Q factor setting.
Gain (dB): filter gain setting.
Freq (Hz): either filter frequency selection or PEQ central frequency setting.