02Er – TILT movement error:
If the head is not located in the default tilt position after start-
up or after a reset command. This message will appear after a
xture reset, if the tilt magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or a defective motor IC drive on the
main PCB).
Accu Fog 1000 Error Codes Accu Fog 1000 Error Codes
When power is applied, the unit will automatically enter a
“reset/test” mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will ash in the display in the form
of “XXer”, “XX” will represent a function number. For example,
when the display shows “02Er,” it means there is some type
of error with the channel 2 motor. If there are multiple errors
during the start-up process they will all ash in the display. For
example: if the xtures has errors on channel 1 and channel 2
at the same time, you will see the error message ash “01Er”
and “02Er” repeated 5 times.
If an error does occur during the initial start-up procedure the
xture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
xture will make the following determinations:
1) 3 or more errors - The xture cannot function properly with
three or more errors therefore the xture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the xture has less than 3 errors, there-
fore most other functions will work properly. The xture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain ashing in the
display as a reminder of internal errors.
01Er – PAN movement error:
If the yoke is not located in the default position after start-up or
after a reset command. This message will appear after a xture
reset, if the pan-yoke’s magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or a defective motor IC drive on the
main PCB).