5. Before use
1. CHECKS
- Check parts are not loose nor missing. This goes especially for the spark plug.
- Check the air intake and outlet for clogging. This auger uses an air-cooled engine. If the air passage is blocked, the engine may overheat.
- Check the air cleaner for dirt. A dirty air cleaner will cause the auger to burn excess fuel.
- Check the spark plug for spark.
2. ADDING OIL (Pic.5)
- Change the oil once after the rst 50 hours and then every 100 hours thereafter. Change oil while engine is warm.
- Add 250 cc of oil (SAE 80-90 gear oil).
- Do not add oil past the drain plug hole. To determine oil level, stand the auger on the drill. Oil level should be at the bottom of the
drain plug hole.
Gear case
Oil ller port
Drain plug hole
Drain plug
Fill oil up to here
Pic.5