Auramax VP 4, D 100 90-00039 [13/32] Installation and set up procedures

Auramax A 4C [13/32] Installation and set up procedures
EN
13
Pic.1
OPTIMA
MAIN TECHNICAL CHARACTERISTICS
Characteristics
A 4
A 5
A 6
B 4
B 5
C 4
C 5
D 4
D 5
D 6
OPTMA 4
OPTIMA 5
RF 4
RF 5
RF 150
RF 6
VP 4
VP 5
VP 150
VP 6
Flange diameter (mm)
100 125 150 100 125 100 125 100 125 150 100 125 100 125 150 160 100 125 150 160
Eciency (m
3
/h) 90 140 250 100 190 70 120 90 140 250 97 183 107 190 280 300 107 190 280 300
Power сonsumption (W) 14 16 16 14 16 14 16 14 16 16 14 14 14 18 22 22 14 18 22 22
Noise level (dB) 35 36 38 35 36 35 36 35 36 38 35 36 35 36 37 38 35 36 37 38
Net weight (kg), doesn’t exceed
0,50 0,60 0,72 0,45 0,65 0,45 0,65 0,50 0,60 0,72 0,44 0,50 0,45 0,55 0,85 0,90 0,31 0,41 0,60 0,66
The fans are designed for connection to AC mains voltage 220-240 V, frequency 50/60 Hz. The characteristics specified are applied at an 50Hz AC frequency. The characteristics
for 60Hz AC frequency are to be checked with the manufacturer.
INSTALLATION AND SET UP PROCEDURES
AURAMAX fans are mounted both with airvents and independently.
AURAMAX fans are intended for wall mounting.
Mounting of AURAMAX fans is carried out as with ventilating air ducts and
independently on a plain vertical or horizontal surface of sucient rigidness for
installation of a product by means of screws. Tolerance range of a mounting surface
in vertical and horizontal directions is ±0,5 mm.
SCHEMATIC DIAGRAMS OF ERA FAN`S CONNECTION
Scheme 1
of fan connectuion (base model)
X- terminal block, 2 pairs
Scheme 2
of fan connection, equipped with - 02 option (pull-chain
switch).
X2- terminal block, 3 pairs
Scheme 3 (for A / D models)
of fan connection, equipped with - 02 option(pull-chain
switch)
X- terminal block, 2 pairs
WIRING DIAGRAM CONNECTION OF AURAMAX FANS
TO THE NETWORK
Connection of fan to the network shown in pic. 1-8
OPTIMA (pic. 1)
remove the decorative front panel
hold the power wire through the cable hole 1 in
the case
strip the insulation on 5-7 mm from the wire end
insert wires into terminal box X and press them
by tap screw
fix the wires by means of cable clamp 2
combine clamps of the decorative panel with
grooves in the case
fix the panel with screw
S3
Legend of circuit breaker S1
on the scheme
Сircuit breaker S1
External switch S2
Built-in switch S3 (pull chain
switch)
Legend of external switch
S2 on the scheme
Legend of built-in switch S3
on the scheme
S3
220-240V
220-240V
S3
220-240V

Содержание