CEILING HEATER THERMOUP TOP 700/1100/1500
The temperature of the side facing the ceiling in operation can reach 60 °C. The required temperature
resistance of the materials of the ceiling coating when using the standard mounting bracket must be at
least 80 °C. When using other materials for the ceiling covering, it is recommended to increase the
distance from the heater to the ceiling, using alternative options to x the device.
Figure 4. ThermoUp Top Heater Radiation
ATTENTION!
The distance from the oor to the ThermoUp Top
heater must be at least 1.8 m.
The distance to the ceiling should be at least 10 cm,
to the walls - at least 50 cm. The distance to objects in
the zone of the heater - not less than 50 cm.
With long-term presence of people or animals in the
heating zone, the distance from them to the heater
must be at least 80 cm.
It is possible to use the standard xing kit of the
ThermoUp Top heater for installation on the wall under
the ceiling in compliance with recommendations for
the height of the suspension.
Installation recommendations
Recommended Heater Suspension
Heater Size
Height, m
ThermoUp Top 700
828 х 186 2,3-3,5
ThermoUp Top 1100
828 х 278 2,5-3,5
ThermoUp Top 1500
828 х 325 2,7-3,5
Table 2