Karcher HDS 12/14-4 ST Eco [30/444] Maintenance and care

Karcher HDS 12/14-4 ST Eco [30/444] Maintenance and care
- 9
Danger
Risk of injury! The main switch of the vacuum cleaner is to be
switched off or the Cekon plug must be unplugged while carrying
out any repairs or maintenance jobs.
Maintenance and care
Maintenance schedule
Time Activity Assembly affected Performance of whom
daily Check hand-
spray gun
Hand spraygun Check whether the hand-spray gun closes tightly
without any leaks. Check the protection mecha-
nism against accidental switching. Replace de-
fective hand-spray guns.
Operator
Check high pres-
sure hoses
Outlets, hoses towards working
machine
Check hoses to see if there are damages. Re-
place defect hoses immediately. Danger of acci-
dent!
Operator
Check the con-
necting line with
mains plug
Electrical connection with plug/
socket
Check the connecting line with mains plug for
damages. If the power cord is damaged, please
arrange immediately for the exchange by an au-
thorized customer service or a skilled electrician.
Operator
weekly or after 40
operating hours
Check oil level Oil tank at the pump If the oil is milky, it needs to be replaced. Operator
Check oil level Oil tank at the pump Check oil level of the pump. Refill oil if required
(Order no. 6.288-016)
Operator
Cleaning the
sieve
Sieve in water inlet See section "Clean sieve". Operator
monthly or after
200 operating
hours
Clean and check
the ignition elec-
trodes
Ignition electrodes located in
the lid of the continuous heater
Unscrew the fuel pipe, dismantle the electrode
holder and clean the electrodes. Check the elec-
trode setting according to the diagram on the fol-
lowing page and make the necessary
adjustments.
Trained op-
erator
Check pump High-pressure pump Check the pump for leaks. If the leakage is more
than 3 drops per minute, call Customer Service.
Operator
Check for inter-
nal deposits
Entire plant Operate the machine using the spray pipe with-
out the high pressure nozzle. If the operating
pressure on the manometer of the machine in-
creases to more than 3 MPa, then the plant
needs to be decalcified. The same is applicable
when an operating pressure of more than 0.7 - 1
MPa is detected while operating the machine
without high pressure pipe (water comes out
freely at the high pressure outlet).
Operator
trained in de-
calcification
Cleaning the
sieve
Sieve in the water shortage
safeguard
See section "Clean sieve". Operator
half-yearly or after
1000 operating
hours
Oil change High-pressure pump Drain off oil. Fill in 1 l new oil (Order no. 6.288-
016). Check oil level in the oil tank.
Operator
check, clean Entire plant Visual inspection of the plant, check high pres-
sure connections to see that they are not leaking,
check that the over-flow valves are not leaking,
check high pressure hoses, pressure tanks,
clean/ replace fuel filters, remove the rust/ calci-
um deposits from the heating coil, clean/ replace
ignition electrodes, clean/ replace burner nozzle,
adjust burner.
Customer
Service
annual Safety check Entire plant Perform a safety inspection as per the applicable
national rules and regulations for liquid spray jets
of the respective country.
Technical
expert
at least every 5
years, recurring
Pressure test Entire plant Perform the pressure test as per manufacturer's
instructions.
Technical
expert
30 EN

Содержание