BATTERY INSPECTION INSP fob ADJ WV Batteries generate explosive hydrogen gas Always follow these preventive measures Charge batteries in a well ventilated area Keep batteries away from fire sparks or open flames e g welding equipment lighted cigarettes etc DO NOT SMOKE when charging or han dling batteries KEEP BATTERIES AND ELECTROLYTE OUT OF REACH OF CHILDREN 1 Remove Rider s seat Refer to FUEL TANK AND SEATS Battery cover 2 Disconnect Battery leads CAUTION ________________________ First disconnect the negative lead then disconnect the positive lead 3 Remove Battery band Battery 4 Check Battery condition Battery condition checking steps Connect a digital voltmeter to the battery terminals Tester lead battery terminal Tester lead battery terminal NOTE ________________________________ The charge state of an MF battery can be checked by measuring the open circuit volt age i e the voltage when the positive ter minal is disconnected 3 39 Open circuit voltage Charging time 12 8V or higher No charging is necessary