Yamaha DRAG STAR XVS650 (1997) [101/360] Insp adj

Содержание

Похожие устройства

BATTERY INSPECTION INSP ADJ Check the condition of the battery using the following charts Example eOpen circuit voltage 12 0V eCharging time 6 5 hours e Charge condition of the battery 20 30 eCharging method for MF batteries CAUTION ________________________ This varies depending on the temperature the state of charge in battery plates and the electro lyte level If it is impossible to set the standard charging current be careful not to over charge When charging the battery be sure to remove it from the motorcycle If charg ing has to be done with the battery mounted on the motorcycle be sure to disconnect the wire at the negative termi nal Never remove the sealing caps of an MF battery Make sure that the charging clips are in full contact with the terminal and that they are not shorted together A cor roded clip on the charger may cause the battery to generate heat in the contact area A weak clip spring may cause sparks Before removing the clips from the bat tery terminals be sure to turn off the charger s power switch The open circuit voltage variation for the MF battery after charging is shown below As shown in the figure the open circuit voltage stabilizes about 30 min utes after charging has been completed Therefore wait 30 minutes after charging is completed before measuring the open circuit voltage Check the Open circuit voltage 3 40