Kramer F-110 [4/14] Overview
![Kramer F-110 [4/14] Overview](/views2/1153717/page4/bg4.png)
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Overview
2
3 Overview
The Kramer F-110 dual-slot wall-plate insert is an XGA line transmitter
that accepts up to a UXGA video signal, encodes it to a twisted pair (TP)
signal, and transmits the TP signal to a compatible TP receiver
1
.
In particular, the F-110:
• Has a resolution of up to UXGA
• Includes the Kramer Power Connect™ feature
• Has a 12V DC power supply
• Fits into various insert mounting surfaces
2
3.1 About the Power Connect Feature
The
Power Connect feature applies as long as the cable can carry power.
This feature is available when using STP cable and the distance does not
exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge
cable should be used
3
. For units which are connected via RJ-45 connectors,
make sure that the shield of the STP cable is connected to the metal casing
of the connectors on both ends of the cable. For units which are connected
via terminal block connectors, the shield of the STP cable must be
connected to a ground terminal on the units at both ends (use the ground
terminal of the power supply connection if necessary).
For a CAT 5 cable exceeding a distance of 50m, separate power supplies
should be connected to the transmitter and to the receiver simultaneously.
3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)
We
recommend that you use Shielded Twisted Pair (STP) cable. There are
different levels of STP cable available, and we advise you to use the best
quality STP cable that you can afford. Our non-skew-free cable, Kramer
BC-STP is intended for analog signals where skewing is not an issue. For
cases where there is skewing, our UTP skew-free cable, Kramer BC-XTP,
may be used. Bear in mind, though, that we advise using STP cables where
possible, since the compliance to electromagnetic interference was tested
using those cables.
Although Unshielded Twisted Pair (UTP) cable might be preferred for long
range applications, the UTP cable should be installed far away from electric
1 For example, the Kramer TP-120 or PT-120
2 For example, TBUS units, wall plate frames or Ackermann insert mounting frames (see section 6
)
3 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances
Содержание
- Kramer electronics ltd 1
- User manual 1
- Contents 2
- Figures 2
- Tables 2
- Getting started 3
- Introduction 3
- About the power connect feature 4
- Overview 4
- Shielded twisted pair stp unshielded twisted pair utp 4
- Achieving the best performance 5
- Figure 1 and table 1 define the f 110 6
- Figure 1 f 110 xga line transmitter 6
- Table 1 f 110 features 6
- Your f 110 xga line transmitter 6
- Connecting the f 110 7
- Wiring the 9 pin terminal block line output connector 9
- Table 2 and figure 4 define the utp cat 5 pinout on the rj 45 connector 10
- Table 2 cat 5 pinout figure 4 cat 5 pinout 10
- Table 3 f 110 applications 10
- Table 3 shows examples of how the f 110 dual slot wall plate insert can be installed in various applications 10
- Using the f 110 10
- Wiring the cat 5 line in line out rj 45 connectors 10
- Using the f 110 11
- Of the f 110 12
- Table 4 lists the technical specifications 12
- Table 4 technical specification 12
- Technical specifications 12
- Except as below this warranty covers all defects in material or workmanship in this product the following are not covered by the warranty 13
- We warrant this product free from defects in material and workmanship under the following terms 13
- Caution caution 14
- For the latest information on our products and a list of kramer distributors visit our web site www kramerelectronics com where updates to this user manual may be found we welcome your questions comments and feedback 14
- Kramer electronics ltd 14
- Safety warning safety warning 14
Похожие устройства
- Kramer W4545 Руководства по эксплуатации
- Kramer W1145 Руководства по эксплуатации
- Kramer WA-45 Руководства по эксплуатации
- Kramer WD-2F Руководства по эксплуатации
- Kramer WU-AA Руководства по эксплуатации
- Kramer WU-BA Руководства по эксплуатации
- Kramer WU-AB Руководства по эксплуатации
- Kramer W-H Руководства по эксплуатации
- Kramer W-DP Руководства по эксплуатации
- Kramer W-DVIA Руководства по эксплуатации
- Kramer W-DVI Руководства по эксплуатации
- Kramer WCP Руководства по эксплуатации
- Kramer WCP-21 Руководства по эксплуатации
- Kramer WCP-2 Руководства по эксплуатации
- Kramer FRAME-1G Руководства по эксплуатации
- Kramer FRAME-2G Руководства по эксплуатации
- Kramer WP-3TB Руководства по эксплуатации
- Kramer FLA-12 Руководства по эксплуатации
- Kramer F-121 Руководства по эксплуатации
- Kramer F-571 Руководства по эксплуатации