Линейные оптические терминалы LTP 97
set services alarm
alarm <parameter value>
ok_as_normalize
<PARAMETER
VALUE>
<VALUE>
battery_power/
channel_flapping/
channel_ont_count_overflow/
channel_state_chabged/
config_change/
config_save/
data_link_layer/
data_link_layer_flapping/
download/
duplicate_mac/
fan/
firmware_update/
free_space/
interface_critical_load/
link/
load_average/
login/
logout/
olt_update/
oms/
ont_config/
ont_config_changed/
ont_dying_gasp/
ont_flapping/
ont_low_rx_power/
ont_physical_layer/
ont_state_changed/
ont_update/
physical_layer_block/
physical_layer_errors/
physical_layer_flapping/
pon_channel_no_ont/
ram/
redundancy_channel_switch/
redundancy_master_channel_fail/
shutdowsn/
system_reboot/
temperature/
type_dummy
false/true
Установить/запретить
отправку трапа “OK при
окончании события
set services alarm cfg
free_ram
<VALUE>
0..100
Установить критическое
значения памяти ОЗУ в
процентах
set services alarm cfg
free_space
<VALUE>
0..100
Установить критическое
значения памяти ПЗУ
в процентах
set services alarm cfg
load_average
15min/1min/5min
<VALUE>
0..255
Установить критическую
загрузку процессора за
1/5/15 минут
set services alarm cfg
max_rpm
<VALUE>
0..65535
Установить
максимальную границу
скорости вентиляторов
set services alarm cfg
min_rpm
<VALUE>
0..65535
Установить
минимальную границу
скорости вентиляторов
set services alarm cfg
temperature 0/1
<VALUE>
0..255
Установить критическую
температуру датчика
0 датчик 1
1 датчик 2