Asus rog maximus viii impact [121/220] Chapter 3

Asus rog maximus viii impact [121/220] Chapter 3
ASUS MAXIMUS VIII IMPACT
3-41
Chapter 3
Extension Fan 1-3 Middle. Duty Cycle (%) [60]
Use the <+> or <-> keys to adjust the middle Extension Fan 1-3 duty cycle.
The values range from 60% to 100%. When the CPU temperature reaches
the middle limit, the Extension Fan 1-3 will operate at the middle duty cycle.
Extension Fan 1-3 Lower Temperature [40]
Use the <+> or <-> keys to adjust the lower limit of the Extension Fan 1-3
temperature. The values range from 0 to 75. The Extension Fan 1-3 will
operate at the minimum duty cycle when the temperature is lower than the
limit.
Extension Fan 1-3 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum Extension Fan 1-3 duty
cycle. The values range from 0% to 100%. When the CPU temperature
is under the limit, the Extension Fan 1-3 will operate at the minimum duty
cycle.
Allow Fan Stop [Disabled]
This function allows the fan to run at 0% duty cycle when the temperature of the source
is dropped below the lower temperature.
Conguration options: [Disabled] [Enabled]
Anti Surge Support [On]
Enable this item for Over Voltage Protection (OVP) and Under Voltage Protection (UVP)
functions.
Conguration options: [On] [Off]