Zyxel IES-5106 [1045/1156] 4 sys multilogin enable command

Zyxel IES-5106 [1045/1156] 4 sys multilogin enable command
Chapter 36 sys Commands
Management Switch Card User’s Guide
1045
where
This command displays the hardware monitor’s statistics.
The following example shows the MSC statistics.
36.3.24 sys multilogin enable Command
Syntax:
sys multilogin enable
<slot>
=
The main chassis slot where the card is located. The fan statistics are included with the
MSC statistics.
ras> sys monitor show 1
'*' indicates a current alarm
voltage:
idx volt current nominal high_lmt low_lmt
--- ---------------- -------- -------- -------- --------
1 2.5V 2.571 2.500 2.700 2.300
2 1.25V 1.242 1.250 1.350 1.150
3 3.3V 3.334 3.300 3.564 3.036
4 1.3V 1.334 1.300 1.404 1.196
5 15V 14.999 15.000 16.200 13.800
temperature:
idx temperature current high_lmt low_lmt
--- ---------------- -------- -------- --------
1 Temp1 29.0 81.0 -10.0
2 Temp2 30.750 82.0 -10.0
3 Temp3 28.750 78.0 -10.0
fan:
idx fan speed current high_lmt low_lmt
--- ---------------- -------- -------- --------
1 FAN1 3337 7000 2000
2 FAN2 3329 7000 2000
3 FAN3 3306 7000 2000
4 FAN4 3239 7000 2000
5 FAN5 3335 7000 2000
6 FAN6 3325 7000 2000
cpu:
idx cpu current high_lmt
--- ---------------- -------- --------
1 CPU1 10 70
memory:
idx memory current high_lmt
--- ---------------- -------- --------
1 MEM1 71 85
packet buffer:
idx packet buffer current high_lmt
--- ---------------- -------- --------
1 PKTBUFF1 0 71

Содержание