Zyxel IES-5106 [174/1156] Chapter 7 diagnostic screens

Zyxel IES-5112 [174/1156] Chapter 7 diagnostic screens
Chapter 7 Diagnostic Screens
Management Switch Card User’s Guide
174
Figure 97 MLT (relay mode)
The following table describes the labels in this screen.
Table 72 MLT
LABEL DESCRIPTION
MLT Use the Slot and Port drop-down list boxes to select the port on an active VoIP line card
you want to configure.
Select test to perform line tests directly from the MSC.
Select relay to allow or prohibit line testing performed by external devices connected to
the VoIP line cards Test In and Test Out ports.
Mode When you select relay, also select the MLT relay mode:
in: allow diagnostic inner loop tests to be initiated by an external device.
out: allow diagnostic outer loop tests to be initiated by an external device.
off: forbid MLT relay testing.
both: allow both inner and outer loop diagnostic tests to be initiated by an external device.
Forced In relay mode, select this to make the configuration change immediately, even if the port
is currently in use.
Test In test mode, click this to perform the specified test.
Set In relay mode, click this to save the current settings (you must also click the Config Save
link on the navigation panel to save your changes to the non-volatile memory when you are
done configuring).
Get Mlt Data Click this to see the results of the latest MLT test performed on the specified line card and
port.
Get Relay Data Click this to see the current MLT relay configuration of the specified line card.
Abort Click this to stop the MLT testing immediately.
The following MLT options are available only in test mode.
Forced Select this to perform the test(s) immediately, even if the specified port is in use.