Zyxel IES-5106 [690/1156] Alarm tablelist command

Zyxel IES-6000 [690/1156] Alarm tablelist command
Chapter 21 alarm Commands
Management Switch Card User’s Guide
690
The following example displays the critical level alarms for all alarm categories and conditions.
21.3.9 alarm tablelist Command
Syntax:
alarm tablelist [<alarm>|all] [<severity>|all] [<fac>|all][<target>[,<target>]]
[<condition>|all]
where
This
command displays the supported alarm list and report settings.
ras> alarm show critical all
[current card alarm]
id state card type heat vol mon down out
--- --------- --------------- ---------------------
1 standby MSC1000G - - - - -
2 active MSC1000G - - - - -
3 - - - - - -
4 - ALC1248G-53 - - - V V
5 active ALC1248G-53 - - - - -
6 - - - - - -
7 - ALC1248G-51 - - - V V
8 - - - - - -
9 - ALC1248G-53 - - - V V
10 - ALC1248G-53 - - - V V
[current alarm list]
no alarm condition severity timestamp source
------ ------ ------------------------ -------- -------------- --------------
1 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
2 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
3 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
4 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
5 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
6 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
7 eqpt +DC_POWER_FAIL critical 12/14 13:46:21 slot 2
<fac>
=
The log facility (local1~local7) that has the device log the syslog messages to
different files in the syslog server. See your syslog program’s documentation for
details.
<target>
=
snmp|syslog|all The type of alarm messages that the device is to send
(SNMP, syslog or all).

Содержание

Скачать