Zyxel IES-5106 Инструкция по эксплуатации онлайн [945/1156] 154532

Zyxel IES-5106 Инструкция по эксплуатации онлайн [945/1156] 154532
Chapter 34 show Commands
Management Switch Card User’s Guide
945
This command displays the status and statistics of E1 link 6 on the IMA group 2 of the line card
installed in slot 2.
Syntax:
show ima performance group <slot-group> [curr15|currday|last24hr|[96q <sq>
<eq>]|[7day <sd> <ed>]
This command displays the statistics of IMA group 2 in slot 2 collected since midnight till now.
In this example output, NE means near end. NE-Failures means the number of IMA group 2 failures
that have been detected by the IMA line card. FE means far end. FE-Failures means the number of
IMA group 2 failures that have been detected by the remote IMA device.
Syntax:
show ima performance link <slot-port> <link-id> [curr15|currday|last24hr|[96q <sq>
<eq>]|[7day <sd> <ed>]
ras> show ima link 2-2 6
Row status code : 0
NE Tx State : usable
NE Rx State : unusableNoGivenReason
FE Tx State : unknow
FE Rx State : unknow
NE Rx Failure Status : fault
FE Rx Failure Status : noFailure
Related Delay : 0
IMA Violation : 0
OIF Anomalies : 0
Tx id : 6 Rx id : 33
NE SES : 9 FE SES : 0
NE UAS : 199766 FE UAS : 0
NE Tx UUS : 0 NE Rx UUS : 199775
FE Tx UUS : 0 FE Rx UUS : 0
NE Tx Num of Failure : 0 NE Rx Num of Failure : 2
FE Tx Num of Failure : 0 FE Rx Num of Failure : 0
Tx Stuff : 441505 Rx Stuff : 0
Rx Test Pattern : 00 Test Porcessing status: disabled
Valid 15 minutes Interval : 96 Invalid 15 minutes Interval : 0
Seconds since current period started : 488
ras> show ima performance group 2-2 currday
Group 2 in Currday Day history : start from 0 to 0
idx NE-Failures FE-Failures IMAUAS
--------------------------------------------
1 0 0 59256

Содержание