Section 5: Purging Air After Adding or Replacing a Secondary Divider Valve Module
Steps 1-8, refer to FIG. 10.
1. Install the new or replacement module to the secondary
divider valve assembly. Also connect the tubing or hoses
to the appropriate lubrication point if the new/replacement
module is a base section.
2. Do not completely tighten the connection(s) at the
lubrication point.
3. Remove the performance indicator or indicator port plug
from the working valve section on the secondary divider
valve assembly corresponding to the outlet port and line
connected to a particular lube point.
4. Attach a hand pump filled with clean, filtered lubricant to
the port on the secondary divider valve that was opened
in Step 3.
5. Operate the hand pump until air-free lubricant is observed
flowing from the loosened connector at the lube point.
6. Tighten the fitting at the lube point while lubricant is still
flowing.
7. Repeat Steps 3 - 6 for any additional lubrication points
connected to the new module.
8. Remove the hand pump and reinstall the performance
indicator or port plug removed in Step 3 into the
secondary divider valve’s open port.
The system is now ready for operation.
FIG. 10
TI11115
MASTER
HAND PUMP
BLEED HOSE
REMOVE INDICATOR
OR PORT PLUG
SECONDARY
LUBE POINT
HERE
NEW VALVE
BLOCK
BLEED
HERE