Moxa TRC-190-DC [16/21] Power supply fuse replacement trc 190 ac power supply module only
![Moxa TRC-190-DC [16/21] Power supply fuse replacement trc 190 ac power supply module only](/views2/1200764/page16/bg10.png)
TRC-190 Powering the TRC-190
3-6
Power Supply Fuse Replacement
(TRC-190-AC, power supply module only)
To replace a fuse on the power supply module does not require to pull the power supply module out of the
chassis.
Replacing the Fuse
ATTENTION
Wear a grounding device and observe electrostatic discharge precautions when replacing the fuse in the power
supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power
supply module.
Follow the instructions below when you need to change the fuse:
1. Set the power switch on the power supply module to “O.”
2. Disconnect the power supply module from the external power source.
3. Remove the fuse from the holder carefully.
4. Install a same-sized fuse with the same current rating in the fuse holder.
NOTE
Failure to use a fuse of
the same size and same rating may damage your power module or even the entire
equipment setup.
5. Connect the power supply module to the external power source.
ATTENTION
Do not connect the power supply module to the external power source before installing it into the chassis.
Failure to observe this may cause the equipment damage, personal injury, or
even death.
Содержание
- Trc 190 user s manual 1
- Copyright notice 2
- Disclaimer 2
- Technical support contact information 2
- Trademarks 2
- Trc 190 user s manual 2
- Www moxa com support 2
- Table of contents 3
- Introduction 4
- Optional accessories 5
- Overview 5
- Package checklist 5
- Standard accessories 5
- Trc 190 introduction 5
- Environmental limits 6
- Mtbf mean time between failures 6
- Physical characteristics 6
- Power requirements 6
- Product specifications 6
- Standards and certifications 6
- Trc 190 introduction 6
- Warranty 6
- Slide in modules 7
- Attention 8
- Installing or removing chassis face plate 8
- Trc 190 slide in modules 8
- Attention 9
- Installing the media converter slide in modules 9
- Trc 190 slide in modules 9
- Replacing the media converter slide in modules 10
- Trc 190 slide in modules 10
- Powering the trc 190 11
- Ac power supply modules 12
- Optional redundant power supply module 12
- Trc 190 powering the trc 190 12
- Attention 13
- Dc power supply modules 13
- Optional power supply modules 13
- Powering the ac power supply module 13
- Trc 190 powering the trc 190 13
- Attention 14
- Power supply module installation 14
- Powering the dc power supply module 14
- Trc 190 powering the trc 190 14
- Power supply module replacement 15
- Trc 190 powering the trc 190 15
- Attention 16
- Power supply fuse replacement trc 190 ac power supply module only 16
- Replacing the fuse 16
- Trc 190 powering the trc 190 16
- Trc 190 rackmounting 17
- Attention 18
- Installing the trc 190 chassis 18
- Trc 190 trc 190 rackmounting 18
- Grounding 19
- Trc 190 trc 190 rackmounting 19
- Troubleshooting 20
- General troubleshooting 21
- Trc 190 troubleshooting 21
Похожие устройства
- Moxa TRC-190-DC Технические характеристики
- Moxa TRC-190-AC Инструкция по эксплуатации
- Moxa TRC-190-AC Технические характеристики
- Moxa TCF-142-M-ST-RM Инструкция по эксплуатации
- Moxa TCF-142-M-ST-RM Технические характеристики
- Moxa TCF-142-S-ST-RM Инструкция по эксплуатации
- Moxa TCF-142-S-ST-RM Технические характеристики
- Moxa TCF-142-M-SC-RM Инструкция по эксплуатации
- Moxa TCF-142-M-SC-RM Технические характеристики
- Moxa TCF-142-S-SC-RM Инструкция по эксплуатации
- Moxa TCF-142-S-SC-RM Технические характеристики
- Moxa CSM-200-1213 Инструкция по эксплуатации
- Moxa CSM-200-1213 Технические характеристики
- Moxa CSM-200-1214 Инструкция по эксплуатации
- Moxa CSM-200-1214 Технические характеристики
- Moxa CSM-200-1218 Инструкция по эксплуатации
- Moxa CSM-200-1218 Технические характеристики
- Moxa PWR-190-AC Инструкция по эксплуатации
- Moxa PWR-190-AC Технические характеристики
- Moxa ICF-1150-M-SC Инструкция по эксплуатации