Moxa TRC-190-DC [21/21] General troubleshooting

Moxa PWR-190-AC [21/21] General troubleshooting
TRC-190 Troubleshooting
5-2
General Troubleshooting
Condition Try this
1. The LED indicator on power
supply module is not illuminated.
Check if the power cord is correctly connected to the power
source.
Check if the power source is supplying power.
Check if the fuse in the fuse holder is not damaged.
Check if the power switch on the panel is set to l
If none of the above, please contact y
our local distributor/reseller
or our technical support staff. Or, write to info@moxa.com.
2. The power LED indicator on the
slide-in module is not illuminated.
Check if the LED indicator on the power supply module is
illuminated. If no, follow the steps for Condition 1.
Check if the power supply module is really connected to the panel.
Check if the slide-in module is correctly attached to the chassis.
If none of the above, please contact our local distributor/reseller
or our technical support staff. Or, write to info@moxa.com
.
3. The power LED indicator on the
front panel is illuminated, but the
data transmission is not working.
Check if the cables are correctly attached to the slide-in module.
Check the pin-assignment of the serial cable
Check if the OP
Mode switch on the front panel is correctly set for
your operation.
Check if the fiber patch cord is not damaged.
Check if the length of the fiber cable is under our claimed distance.
If none of above, please contact our local distributor/reseller or
our technical support staff. Or, write to info@moxa.com
.