Bosch BSG 82480 [15/154] Megafilt

Bosch BSG 82480 [15/154] Megafilt
*
Dependent on model
Figure
The required suction level can be selected by infinitely
variable adjustment of the suction regulator.
Low
suction range:
For vacuuming delicate fabrics, e.g. curtains.
Medium
suction range:
For daily vacuuming of lightly soiled floors.
High
suction range:
For vacuuming durable floor coverings, hard floors
and for heavily soiled surfaces.
Replacing the MEGAfilt
®
SuperTEX dust bag
Figure
If the filter status indicator flashes when the nozzle
is lifted from the floor and the highest suction set-
ting is set and then, after a short while, switches to
a permanent red, the dust bag must be changed,
even if it does not appear to be full. In this case it is
essential to change the dust bag due to the type of
material it contains.
As soon as the indicator switches to permanent red,
the vacuum cleaner is switched down to the next
power setting.
The vacuum power setting cannot be changed until
you have switched the appliance off and on again.
Open the dust container lid by moving the locking
lever in the direction of the arrow.
Figure
Seal the MEGAfilt
®
SuperTEX dust bag by pulling the
locking tab and then remove the bag.
Figure
Insert a new MEGAfilt
®
SuperTEX dust bag into the
holder and close the dust container lid.
!
Caution: the dust container lid will only close if a
MEGAfilt
®
SuperTEX dust bag or the textile filter or
dust container is inserted.
If the filter status indicator still flashes red after the
dust bag has been changed, please check whether
the nozzle, tube or flexible hose is blocked.
29
28
27
26
Cleaning the permanent filter and Microsan filter
The filters must be cleaned:
If you vacuum until the filter status indicator lights up.
After any malfunctions, i.e. after a blockage is
cleared.
At least every six months.
Figure
Unlock the filter holder by pressing the two lugs in
the direction of the arrow and open it.
Figure
Remove the Microsan and permanent filters and
clean by tapping out the dirt.
!
Caution: the Microsan filter must be hand washed
every six months or when very dirty, and must only
be refitted in the appliance after they have been
allowed to dry for about 24 hours.
Malfunctions
Removing a blockage in the dust container.
Figure
Empty the container (see Figure 20)
Loosen the blockage, e.g. with a screw driver, and
remove by tapping it out.
Close the bottom flap, making sure that you hear it
click into place.
Using
MEGAfilt
®
SuperTEX dust bags
If necessary, a MEGAfilt
®
SuperTEX dust bag can be
used instead of the dust container.
Figure
Open the dust bag compartment lid (see Figure 18)
Take out the dust container (see Figure 19) and
insert the MEGAfilt
®
SuperTEX dust bag.
Close the dust bag compartment lid.
25
24
23
22
en
13

Содержание

Скачать