3.2.3 Configuring Global MSTP Parameters
Follow these steps to configure the global MSTP parameters of the switch:
Step 1 configure
Enter global configuration mode.
Step 2 spanning-tree priority
pri
Configure the priority of the switch for comparison in CIST.
pri
: Specify the CIST priority of the switch. The valid values are from 0 to 61440, which are
divisible by 4096, and the default value is 32768. The switch with the lower value has the higher
priority.
CIST priority the priority of a switch in CIST. The switch with the highest priority will be elected
as the root bridge in CIST.
Step 3 spanning-tree timer {[ forward-time
forward-time
] [ hello-time
hello-time
] [ max-age
max-
age
]}
(Optional) Configure the Forward Delay, Hello Time and Max Age.
forward-time:
Specify the value of Forward Delay. The valid values are from 4 to 30 in seconds,
and the default value is 15. Forward Delay is the time for the port to transit its state after the
network topology is changed.
hello-time:
Specify the value of Hello Time. The valid values are from 1 to 10 in seconds, and the
default value is 2. The root bridge sends configuration BPDUs at an interval of Hello Time to
check whether the links are failed.
max-age:
Specify the value of Max Age. The valid values are from 6 to 40 in seconds, and the
default value is 20. Max Age is the maximum time the switch can wait without receiving a BPDU
before attempting to regenerate a spanning tree.
Step 4 spanning-tree hold-count
value
(Optional) Configure the maximum number of BPDU packets transmitted per Hello Time
interval.
value:
Specify the maximum number of BPDU packets transmitted per Hello Time interval. The
valid values are from 1 to 20 pps, and the default value is 5.