Tp-Link T1600G-28PS (TL-SG2424P) [718/754] Using the cli

Tp-Link T1600G-28PS (TL-SG2424P) [718/754] Using the cli
Configuration Guide 696
Managing SNMP & RMON Notification Configurations
4) Click Create.
3.2 Using the CLI
3.2.1 Configuring the Host
Configure parameters of the NMS host and packet handling mechanism.
Step 1 configure
Enter global configuration mode.
Step 2 snmp-server host
ip udp-port user-name
[smode { v1 | v2c | v3 }] [slev {noAuthNoPriv |
authNoPriv | authPriv }] [type { trap | inform}] [retries
retries
] [timeout
timeout
]
Configure parameters of the NMS host and packet handling mechanism.
ip:
Specify the IP address of the NMS Host in IPv4 or IPv6. Please make sure the IP addresses
of the Host and the switch are able to reach to each other.
udp-port:
Enter the name used by the NMS. When the NMS uses SNMPv1 or SNMPv2c, enter
the Community Name; when the NMS uses SNMPv3, enter the User Name of the SNMP
Group.
user-name:
Enter a view to allow it to be accessed by the community. The name contains 1
to 61 characters.
v1 | v2c | v3 :
Choose a security mode for the SNMP group from the following: SNMPv1,
SNMPv2c, SNMPv3.
noAuthNoPriv | authNoPriv | authPriv:
For SNMPv3 groups, choose a security level from
noAuthNoPriv (no authorization and no encryption), authNoPriv (authorization and no
encryption), authPriv (authorization and encryption). The defaut is noAuthNoPriv. Please
note that if you have chosen v1 or v2c as the security mode, security level cannot be
configured.
trap | inform:
Choose the information type which is only for SNMPv2c or SNMPv3; the default
is trap. When the NMS receives a trap message, it will not send a response to the switch.
Thus the switch cannot determine whether the trap is received or not, and the trap that is
not received will not be resent. When the NMS receives an Inform message, it will send a
response to the switch. If the switch does not receive a response within the Timeout interval,
it will resend the Inform message. Therefore, Informs are more reliable than Traps.
retries :
Set the retry times for Inform messages. The range is 1 to 255 and the default is 3. The
switch will resend the Inform message if it does not receive response from the NMS within
the timeout interval. And it will stop sending Inform message when the retry times reaches
the limit.
timeout :
Set the length of time that the switch waits for a response. The range is 1 to 3600
seconds; the default is 100 seconds. The switch will resend the Inform message if it does not
receive a response from the NMS within the timeout interval.