Tp-Link T1600G-28PS (TL-SG2424P) [735/754] Alarm variable bpkt

Tp-Link T1600G-28PS (TL-SG2424P) [735/754] Alarm variable bpkt
Configuration Guide 713
Managing SNMP & RMON RMON Configurations
f-event:
Enter the event entry index from 1 to 12 to bind it to the falling threshold. The event
entry will be triggered when the sampling value goes below the preset threshold.
rise | fall | all: Choose an alarm type; the default is all. Rise indicates that the alarm is triggered
only when the sampled value exceeds the rising threshold. Fall indicates that the alarm is
triggered only when the sampled value is below the falling threshold. All indicates that the
alarm is triggered when the sampled value exceeds the rising threshold or is below the falling
threshold.
owner-name:
Enter the owner name of the entry using 1 to 16 characters. The default name is
monitor.
interval:
Set the sampling interval. The value ranges from 10 to 3600 seconds; the default is
1800 seconds.
Step 3 show rmon alarm [
index
]
Displays the specified alarm entry and related configurations.
index:
Enter the index of alarm entries that you want to view. The range is 1 to 12, and the
format is 1-3 or 5.
Step 4 end
Return to privileged EXEC mode.
Step 5 copy running-config startup-config
Save the settings in the configuration file.
The following example shows how to set an alarm entry to monitor BPackets on the switch. Set
the related Statistics entry ID as 1, the sample type as Absolute, the rising threshold as 3000, the
related rising event entry index as 1, the falling threshold as 3000, the related falling event index
as 2, the alarm type as all, the notification interval as 10 seconds, and the owner of the entry as
monitor:
Switch#configure
Switch(config)#rmon alarm 1 stats-index 1 alarm-variable bpkt s-type absolute rising-
threshold 3000 rising-event-index 1 falling-threshold 3000 falling-event-index 2 a-type all
interval 10 owner monitor
Switch(config)#show rmon alarm
Index-State: 1-Enabled
Statistics index: 1
Alarm variable: BPkt
Sample Type: Absolute
RHold-REvent: 3000-1