Configuration Guide 707
Managing SNMP & RMON RMON Configurations
Follow these steps to configure alarm:
1) Select an alarm entry, choose a variable to be monitored, and associate the entry with a
statistics entry.
Index Displays the index of alarm entries. There are 12 alarm entries all together.
Variable Set the alarm variable to be monitored. The switch will monitor the
specified variable in sample intervals and act in the set way when the alarm
is triggered. The default variable is RecBytes.
RecBytes: Total received bytes.
RecPackets: Total received packets.
BPackets: Total broadcast packets.
MPackets: Total multicast packets.
CRC&Align ERR: Packets that range from 64 to 1518 bytes and contain FCS
Error or Alignment Error.
Undersize: Packets that are smaller than 64 bytes.
Oversize: Packets that are larger than 1518 bytes.
Jabbers: Packets that range from 64 to 1518 bytes and contain FCS Error or
Alignment Error.
Collisions: Collision times in the network segment.
64, 65-127, 128-255, 256-511, 512-1023, 1024-10240: Total packets of the
specified size.
Statistics Associate the alarm entry with a statistics entry. Then the switch monitors
the specified variable of the statistics entry.
2) Set the sample type, the rising and falling threshold, the corresponding event action, and the
alarm type of the entry.
Sample Type Set the sampling method of the specified variable; the default is absolute.
Absolute: Compare the sampling value against the preset threshold.
Delta: The switch obtains the difference between the sampling values
of the current interval and the previous interval, and then compares the
difference against the preset threshold.
Rising Threshold Set the rising threshold of the variable. When the sampled value exceeds
the threshold, the system will trigger the corresponding Rising Event. The
ranges are from 1 to 2147483647; the default is 100.
Rising Event Specify the index of the event that will be triggered when the sampled
value exceeds the preset threshold.