Supermicro SYS-1028R-WC1RT — руководство пользователя для серверов с мощным охлаждением и питанием [126/128]

Превью страниц Страница 126 / 128
Supermicro SYS-1028R-WC1RT [126/128] System cooling
B-2
SUPERSERVER 1027R-73DBRF User's Manual
Weight
44 lbs. (20 kg.)
System Cooling
Five 4-cm counter-rotating fans
Note: The system cooling fans are NOT redundant, hot-plug.
Power Supply Input Requirements
AC Input Voltage: 100V - 240V AC auto-range
Rated Input Current:
700W 100-140Vac: 8-6A, 50-60Hz
750W 200-240Vac: 4.3-3.8A, 50-60Hz
Power Supply Output
Rated Output Power: 700 Watt (Part# PWS-706P-1R)
Rated Output Voltages: +12V (700W: 58A @ 90V-140VAC, 750W: 62A @ 180-
264VAC), +5Vsb (3A)
Operating Environment
Operating Temperature: 0º to 50º C (32º to 122º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Note: The system power supplies are redundant, hot-plug.
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN
61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada),
CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate

Содержание

384

Изучите характеристики и требования к системам охлаждения и питания серверов. Узнайте об условиях эксплуатации и соблюдении стандартов безопасности.