Mitsubishi Electric PLA-RP125BA / PUH-P125YHAR [8/38] Electrical work
![Mitsubishi Electric PLA-RP50BA / PUHZ-ZRP50VHA [8/38] Electrical work](/views2/1330991/page8/bg8.png)
8
S1
S2
S3
L
N
BLUE
BLUE
YELLOW
YELLOW
CN01
CN01
BLACK
CN01
BLACK
S1
S2
S3
L
N
YELLOW
BLUE
BLUE
YELLOW
CN01
6. Electrical work
6.1.2. Separate indoor unit/outdoor unit power supplies (For PUHZ application only)
The following connection patterns are available.
The outdoor unit power supply patterns vary on models.
1:1 System
* The indoor power supply terminal kit is required.
S1
S2
L
N
1
2
L
N
S1
S2
S3
1
2
L
N
S1
S2
S3
1
2
L
N
S1
S2
S3
1
2
L
N
S1
S2
S3
S3
AB C
D
E
JBC
F
H
GGGG
K
K
K
H
H
H
* Affi x label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.
A Outdoor unit power supply
B Earth leakage breaker
C Wiring circuit breaker or isolating switch
D Outdoor unit
E Indoor unit/outdoor unit connecting cables
F Remote controller
G Indoor unit
H Option
J Indoor unit power supply
* The indoor power supply terminal kits are required.
If the indoor and outdoor units have separate power supplies, refer to the table
below. If the indoor power supply terminal kit is used, change the indoor unit elec-
trical box wiring refering to the fi gure in the right and the DIP switch settings of the
outdoor unit control board.
* Affi x label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.
A Outdoor unit power supply
B Earth leakage breaker
C Wiring circuit breaker or isolating switch
D Outdoor unit
E Indoor unit/outdoor unit connecting cables
F Remote controller
G Indoor unit
H Option
J Indoor unit power supply
K Indoor unit earth
ON
OFF 1 2
(SW8)
3
Indoor power supply terminal kit (option)
Indoor unit electrical box connector
connection change
Label affi xed near each wiring diagram
for the indoor and outdoor units
Outdoor unit DIP switch settings (when
using separate indoor unit/outdoor unit
power supplies only)
Indoor unit specifi cations
Required
Required
Required
*1. A breaker with at least 3.0 mm contact separation in each pole shall be provided. Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase conductors of the supply.
*2. Max. 120 m
*3. The 10 m wire is attached in the remote controller accessory. Max. 500 m
*4. The fi gures are NOT always against the ground.
Notes: 1. Wiring size must comply with the applicable local and national code.
2.
Power supply cords and indoor unit/outdoor unit connecting cords shall not be lighter than polychloroprene sheathed fl exible cord.
(Design 60245 IEC 57)
3. Install an earth longer than other cables.
Option
Connectors (connections of initial setting
are for indoor unit power supplied from
outdoor unit)
Indoor unit power supplied from outdoor unit
(initial setting)
If the indoor and
outdoor units have
separate power
supplies, change the
connections of the
connectors as shown
in the following
fi gure.
Connectors
Indoor unit
control board
Separate indoor unit/outdoor unit power sup-
plies
Option
Indoor unit
control board
* There are 3 types of labels (labels A, B and C). Affi x the appropriate labels to the
units according to the wiring method.
Simultaneous twin/triple/quadruple system
1:1 System
Set the SW8-3 to ON.
Indoor unit model PLA
Indoor unit power supply ~/N (single), 50 Hz, 230 V
Indoor unit input capacity
Main switch (Breaker)
*1
16 A
Wiring
Wire No. ×
size (mm
2
)
Indoor unit power supply & earth 3 × Min. 1.5
Indoor unit-Outdoor unit *2 2 × Min. 0.3
Indoor unit-Outdoor unit earth –
Remote controller-Indoor unit *3 2 × 0.3 (Non-polar)
Circuit
rating
Indoor unit L-N *4 230 V AC
Indoor unit-Outdoor unit S1-S2 *4 –
Indoor unit-Outdoor unit S2-S3 *4 24 V DC
Remote controller-Indoor unit *4 12 V DC
Never splice the power cable or the indoor-outdoor connection cable, otherwise it may result in a smoke, a fi re or communication failure.
Warning:
S1
S2
L
N
1
2
L
N
S1
S2
S3
S3
A
CB
D
J
E
B
C
F
G
H
Содержание
- Air conditioners кондиционеры 1
- Deutsch 1
- English 1
- Español 1
- Français 1
- Installatiehandleiding 1
- Installation manual 1
- Installationshandbuch 1
- Installationsmanual 1
- Italiano 1
- Manual de instalación 1
- Manual de instalação 1
- Manuale di installazione 1
- Manuel d installation 1
- Montaj elki tabi 1
- Nederlands 1
- Pla rp ba series pla zrp ba series 1
- Português 1
- Svenska 1
- Türkçe 1
- Εγχειριδιο οδηγιων εγκαταστασησ 1
- Ελληνικά 1
- Руководство по установке 1
- Русский 1
- Before electric work 2
- Before installation environment 2
- Before installation or relocation 2
- Before starting the test run 2
- Contents 2
- Note the phrase wired remote controller in this installation manual refers only to the par 31maa if you need any information for the other remote controller please refer to either the installation manual or initial setting manual which are included in these boxes 2
- Safety precautions 2
- Ceiling openings and suspension bolt installation locations fig 3 2 3
- Check the indoor unit accessories fig 3 1 3
- Fig 3 1 3
- Fig 3 2 3
- Fig 3 3 3
- Installation location 3
- Installing the indoor unit 3
- Refrigerant and drainage piping locations of indoor unit 3
- Branch duct hole and fresh air intake hole fig 3 4 4
- Confi rming the position of main unit and tightening the suspension bolts fig 3 8 4
- Fig 3 4 4
- Fig 3 5 4
- Fig 3 6 fig 3 7 4
- Fig 3 8 4
- Installing the indoor unit 4
- Suspension structure give site of suspension strong structure fig 3 5 4
- Unit suspension procedures fig 3 6 4
- Connecting pipes fig 4 1 5
- Fig 4 1 5
- Fig 4 2 5
- Installing the refrigerant piping 5
- Precautions 5
- Drainage piping work 6
- Drainage piping work fig 5 1 6
- Fig 4 3 6
- Fig 5 1 6
- Fig 5 2 6
- For twin triple combination 6
- Indoor unit fig 4 3 6
- Installing the refrigerant piping 6
- Electrical work 7
- Fig 6 1 7
- Indoor unit fig 6 1 7
- 1 system 8
- Electrical work 8
- On off 1 2 sw8 3 8
- Separate indoor unit outdoor unit power supplies for puhz application only 8
- Simultaneous twin triple quadruple system 8
- Electrical work 9
- Fig 6 2 9
- Fig 6 3 9
- Fig 6 4 9
- For wired remote controller 9
- For wireless remote controller 9
- Remote controller 9
- Electrical work 10
- Fig 6 5 fig 6 6 10
- Fig 6 7 fig 6 8 10
- Fig 6 9 10
- Function setting on the unit selecting the unit functions 10
- Function settings 10
- Electrical work 11
- Fig 6 10 11
- Function setting on the remote controller 11
- Electrical work 12
- Explanation of word refrigerant address no and unit no are the numbers given to each air conditioner outlet no is the number given to each outlet of air conditioner refer to the right up down air direction is the direction angle to fi x 12
- Fixed setting 12
- How to set the fi xed up down air direction only for wired remote controller and puhz pu h application 12
- Only the particular outlet can be fixed to certain direction with the procedures below once fi xed only the set outlet is fi xed every time air conditioner is turned on other outlets follow up down air direction setting of the remote controller 12
- Remote controller setting 12
- Before test run 13
- Electrical work 13
- Test run 13
- Using wired remote controller 13
- Fig 7 1 14
- Fig 7 2 14
- Fig 7 3 14
- Fig 7 4 14
- Self check 14
- Test run 14
- Using sw4 in outdoor unit 14
- Test run 15
- Check of drainage fig 7 5 16
- Fig 7 5 16
- System control 16
- Test run 16
- Checking the contents fig 9 1 17
- Fig 9 1 17
- Fig 9 2 17
- Fig 9 3 17
- Fig 9 4 17
- Fig 9 5 17
- Installing the grille 17
- Preparations fig 9 5 17
- Preparing to attach the grille fig 9 2 17
- Removing the corner panel fig 9 4 17
- Removing the intake grille fig 9 3 17
- Selection of the air outlets 17
- Fig 9 10 18
- Fig 9 6 18
- Fig 9 7 18
- Fig 9 8 18
- Fig 9 9 18
- Installation of i see sensor corner panel fig 9 10 18
- Installing the grille 18
- Installing the intake grille fig 9 9 18
- Securing the grille fig 9 7 18
- Temporary installation of the grille fig 9 6 18
- Wire connection fig 9 8 18
- Easy maintenance function 19
- Fig 9 11 19
- Installing the grille 19
- Locking the up down airfl ow direction fig 9 11 19
- Меры предосторожности 20
- Меры предосторожности 00 2 место установки 01 3 установка внутреннего прибора 01 4 прокладка труб хладагента 03 5 дренажные трубы 04 20
- Перед тестовым прогоном 20
- Перед установкой или перемещением 20
- Перед установкой окружающая среда 20
- Перед электрическими работами 20
- Содержание 20
- Электрические работы 05 7 выполнение испытания 211 8 управление системой 14 9 установка вентиляционной решетки 15 10 функция простого техобслуживания 17 20
- Fig 3 1 21
- Fig 3 2 21
- Fig 3 3 21
- Место установки 21
- Проверьте наличие дополнительных прина длежностей к внутреннему прибору fig 3 1 21
- Расположение отверстия в потолке и навесных болтов fig 3 2 21
- Расположение труб хладагента и дренажных труб для внутреннего блока 21
- Установка внутреннего прибора 21
- Fig 3 4 22
- Fig 3 5 22
- Fig 3 6 fig 3 7 22
- Fig 3 8 22
- Отверстие для ответвления вентиляционного канала и входное отверстие для свежего воздуха fig 3 4 22
- Подвесная конструкция обеспечьте прочность на месте подвешивания fig 3 5 22
- Порядок подвешивания прибора fig 3 6 22
- Проверка расположения главного прибора и затягивание навесных болтов fig 3 8 22
- Установка внутреннего прибора 22
- Fig 4 1 23
- Fig 4 2 23
- Меры предосторожности 23
- Прокладка труб хладагента 23
- Соединение труб fig 4 1 23
- Fig 4 3 24
- Fig 5 1 24
- Fig 5 2 24
- Внутренний прибор fig 4 3 24
- Для комбинации из двух трех элементов 24
- Дренажные трубы 24
- Дренажные трубы fig 5 1 24
- Прокладка труб хладагента 24
- Fig 6 1 25
- G g g g 25
- Внутренний прибор fig 6 1 25
- Электрические работы 25
- On off 1 2 sw8 3 26
- Если у внутреннего и наружного приборов различные источники электропитания см таблицу ниже при использовании комплекта клемм источника электропитания внутреннего прибора замените проводку распределительной коробки внутреннего прибора в соответствии с рисунком справа и измените настройки микропереключателя панели управления наружного прибора 26
- Изменение соединения разъема распределитель ной коробки внутреннего прибора 26
- Комплект клемм источника электропитания внутреннего прибора дополнительно 26
- Настройка микропереключателя наружного прибора только при использовании отдельных источников электропитания для внутреннего прибора наружного прибора 26
- Одновременная двойная тройная четверная система 26
- Система 1 1 26
- Электрические работы 26
- Fig 6 2 27
- Fig 6 3 27
- Fig 6 4 27
- Для беспроводного пульта дистанционного управления 27
- Для проводного пульта дистанционного управления 27
- Пульт дистанционного управления 27
- Электрические работы 27
- Fig 6 5 fig 6 6 28
- Fig 6 7 28
- Fig 6 8 28
- Fig 6 9 28
- Установки функций 28
- Функциональная настройка прибора выбор функций прибора 1 для проводного пульта дистанционного управления 28
- Электрические работы 28
- Fig 6 10 29
- Функциональная настройка на пульте дистанционного управления 29
- Электрические работы 29
- Порядок настройки фиксированного направленного вниз потока воздуха только для проводного пульта дистанционного управле ния и для применения puhz pu h 30
- Пояснение терминов охладителя и изделия это номера присваиваемые каж дому кондиционеру выпускного отверстия это номер каждого выпускного отверс тия кондиционера см рисунок справа направление воздуха вверх вниз это фиксируемое направление угол 30
- Примечание 0 означает все отверстия 30
- Установка пульта 30
- Фиксация 30
- Электрические работы 30
- Выполнение испытания 31
- Перед пробным прогоном 31
- Электрические работы 31
- Fig 7 1 32
- Fig 7 2 32
- Fig 7 3 32
- Fig 7 4 32
- Выполнение испытания 32
- Использование sw4 в наружном блоке 32
- Самодиагностика 32
- Выполнение испытания 33
- Fig 7 5 34
- Выполнение испытания 34
- До завершения электрических работ 34
- После завершения электрических работ 34
- Проверка дренажа fig 7 5 34
- Управление системой 34
- Fig 9 1 35
- Fig 9 2 35
- Fig 9 3 35
- Fig 9 4 35
- Fig 9 5 35
- Выбор вытяжных отверстий 35
- Подготовка fig 9 5 35
- Подготовка к установке вентиляционной решет ки fig 9 2 35
- Проверка содержимого комплекта fig 9 1 35
- Удаление воздухозаборной решетки fig 9 3 35
- Удаление угловой панели fig 9 4 35
- Установка вентиляционной решетки 35
- Fig 9 10 36
- Fig 9 6 36
- Fig 9 7 36
- Fig 9 8 36
- Fig 9 9 36
- Временная установка вентиляционной решетки fig 9 6 36
- Крепление вентиляционной решетки fig 9 7 36
- Примечание не оставляйте излишек проволочного вывода в электрической ответвительной коробке прибора 36
- Соединение проводов fig 9 8 36
- Установка вентиляционной решетки 36
- Установка воздухозаборной решетки fig 9 9 36
- Установка угловой панели i see sensor fig 9 10 36
- Fig 9 11 37
- Блокировка направления воздушного потока вверх вниз fig 9 11 37
- Проверка 37
- Установка вентиляционной решетки 37
- Функция простого техобслуживания 37
Похожие устройства
- Mitsubishi Electric PLA-RP125BA / PUH-P125YHAR Руководство по установке
- Mitsubishi Electric PLA-RP125BA / PUH-P125YHAR Сертификат
- Mitsubishi Electric PLA-RP100BA / PUHZ-ZRP100YKA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP100BA / PUHZ-ZRP100YKA Руководство по установке
- Mitsubishi Electric PLA-RP100BA / PUHZ-ZRP100YKA Сертификат
- Mitsubishi Electric PLA-ZRP140BA / PUHZ-ZRP140VKA Инструкция по эксплуатации
- Mitsubishi Electric PLA-ZRP140BA / PUHZ-ZRP140VKA Инструкция по установке
- Mitsubishi Electric PLA-ZRP100BA / PUHZ-SHW112VHA Инструкция по эксплуатации
- Mitsubishi Electric PLA-ZRP100BA / PUHZ-SHW112VHA Инструкция по установке
- Victoria Arduino Adonis 3 Gr белая Инструкция по эксплуатации
- Victoria Arduino Athena leva 3 Gr латунь 220В Инструкция по эксплуатации
- Victoria Arduino Adonis T3 2 Gr белая Инструкция по эксплуатации
- Victoria Arduino Athena leva 2 Gr латунь 380В Инструкция по эксплуатации
- Victoria Arduino Athena leva 2 Gr медь 220В Инструкция по эксплуатации
- Victoria Arduino Athena leva 2 Gr латунь 220В Инструкция по эксплуатации
- Victoria Arduino Venus Bar 2 Gr S медь Инструкция по эксплуатации
- Smeg SF4120VC Инструкция по эксплуатации
- Victoria Arduino Athena leva 3 Gr медь 220В Инструкция по эксплуатации
- Victoria Arduino Adonis T3 3 Gr белая Инструкция по эксплуатации
- Smeg SF4390VCX Инструкция по эксплуатации