FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам
нормативних документів та вимогам, що передбачені чинними законодавчими актами України.
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at http://www.tp-link.com/en/ce
Safety Information
• Keep the device away from water, fire, humidity or hot environments.
• Do not attempt to disassemble, repair, or modify the device.
• Do not use damaged charger or USB cable to charge the device.
• Do not use any other chargers than those recommended
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Содержание
88- Installation guide
- Related document
- Conventions
- Audience
- About this installation guide
- Chapter 3 lightning protection 10
- Chapter 2 installation 04
- Chapter 1 introduction 01
- Appendix b specifications 22
- Appendix a troubleshooting 21
- Jetstream 24 port gigabit stackable smart switch with 4 10ge sfp slots
- Contents
- Chapter 5 configuration 18
- Chapter 4 connection 16
- Tp link gigabit smart switch designed for workgroups and departments provides wire speed performance and abundant l2 management features it provides a variety of service features and multiple powerful functions with high security
- The front panel of t1700g 28tq is shown as the following figure
- The eia standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks qos and igmp snooping filtering optimize voice and video application link aggregation increases aggregated bandwidth optimizing the transport of business critical data snmp rmon web and cli log in bring abundant management policies tp link gigabit smart switch integrates multiple functions with excellent performance and is friendly to manage which can fully meet the need of the users demanding higher networking performance
- T1700g 28tq also supports stacking of up to 6 units thus providing flexible scalability and protective redundancy for your networks
- Product overview
- Front panel
- Chapter 1 introduction
- Appearance
- Designed to display the stack unit id of the switch for the switch that does not join any stack system it displays its default unit id to modify the default unit number please logon to the gui of the switch and go to stack stack management stack config page and configure the new unit id the new unit id will take effect after you reboot the switch
- Designed to connect to the device with a bandwidth of 10mbps 100mbps or 1000mbps each has a corresponding link act led and a 1000mbps led
- Data is being transmitted or received
- 100 1000mbps rj45 port
- Unit id led
- Sfp port
- Press this button for 5 seconds or above to reset the software setting back to factory default settings
- Port feature
- Port 25 28 designed to install the 1gbps sfp transceiver 10gbps sfp transceiver or sfp cable
- Jetstream 24 port gigabit stackable smart switch with 4 10ge sfp slots
- Rear panel
- Power socket
- Kensington security slot
- Grounding terminal
- Safety precautions
- Package contents
- Chapter 2 installation
- Site requirements
- Installation tools
- Desktop installation
- Rack installation
- Product installation
- Stacking using sfp port
- Configuration and connection
- Power on sequence of the stack switches
- Requirements for cabling outdoors
- Chapter 3 lightning protection
- Cabling reasonably
- When cabling indoors keep a certain distance away from the devices that may cause high frequency interferences such as down conductor cable powerline power transformer and electromotor
- The two diagrams below demonstrate parallel net length and parallel overlapping net height
- The main cable should be paved in the metal raceway of the access shaft when cabling keep the loop area formed by the cable itself as small as possible
- Requirements for the distance between ethernet cable and other pipelines are shown in the table
- Requirements for the distance between ethernet cable and high power electric devices are in following tables
- Requirements for cabling indoors
- Note the above minimum net length height is required when metal raceway is not used if any requirements cannot be met you can add a steel tube or metal raceway for shielding
- Connect to ground
- Note for the device without grounding terminal please refer to the first way connecting to the ground via the power supply only
- Jetstream 24 port gigabit stackable smart switch with 4 10ge sfp slots
- In different environments the device may be grounded differently the following will instruct you to connect the device to the ground in two ways connecting to the grounding bar or connecting to the ground via the power cord please connect the device to ground in the optimum way according to your specific operation environment
- If the device is installed in the normal environment the device can be grounded via the pe protecting earth cable of the ac power supply as shown in the following figure
- Connecting to the ground via the power supply
- Connecting the device to ground is to quickly release the lightning over voltage and over current of the device which is also a necessary measure to protect the body from electric shock
- Connecting to the ground via the grounding terminal
- Verify installation
- Sfp port
- Ethernet port
- Chapter 4 connection
- Power on
- Initialization
- Configure the switch via gui
- Chapter 5 configuration
- Configure the switch using cli
- You are recommended to check the following items
- The pwr led should be lit up when the power system works normally if the pwr led worked abnormally please take the following steps
- Q3 what could i do if i could not access the web based configuration page
- Q2 why does the pwr led work abnormally
- Q1 what could i do if i forgot the username and password of the switch
- Press the reset button for at least 5 seconds to reset the system the system will be reset to the factory default settings and the default login user name and password are both admin
- Appendix a troubleshooting
- Jetstream 24 port gigabit stackable smart switch with 4 10ge sfp slots
- Appendix b specifications
- Safety information
- Industry canada statement
- Fcc statement
- Eu declaration of conformity
- Ce mark warning
Похожие устройства
-
Tp-Link TL-SM321B-2Инструкция по инсталляции -
Tp-Link TL-SM321A-2Руководство по установке -
Tp-Link tl-sg5428Руководство по установке -
Tp-Link tl-sg108eИнструкция по эксплуатации -
Tp-Link LS1005GИнструкция по эксплуатации -
Tp-Link LS1005GИнструкция по эксплуатации -
Tp-Link LS105GИнструкция по эксплуатации -
Tp-Link LS108GИнструкция по эксплуатации -
Tp-Link TL-SF1008P V1Rackmount Switch_EU2_12Languages__ Installation Guide -
Tp-Link TL-SF1008P V1Руководство пользователя -
Tp-Link TL-SF1008P V3Rackmount Switch_EU2_12Languages__ Installation Guide -
Tp-Link TL-SF1008P V3Руководство пользователя
Узнайте о соответствии устройства стандартам FCC и CE, а также о мерах безопасности при его использовании. Важные рекомендации для пользователей.