1507/1503
Users Manual
8
Table 4 Display Indicators (cont.)
Indicator Description
P d Polarization index or dielectric
absorption ratio test is selected
ZERO Ohms lead zero is active.
VAC, VDC, Ω,
kΩ, MΩ, GΩ
Measurement units
88.8.8 Primary display
V
DC
Volts
1888 Secondary display
COMPARE Indicates selected pass/fail compare
value.
t Insulation test indicator. Appears when
insulation test voltage is present.
Table 5. Error Messages
Message Description
batt
Appears on the primary display and
indicates that the battery is too low for
reliable operation. The Tester will not
operate at all until the battery is replaced.
The B also appears when batt is on the
primary display.
> Indicates an out of range value.
CAL Err Invalid calibration data. Calibrate the Tester.
Содержание
58- 1503 insulation testers users manual
- Users manual
- Insulation testers
- Limited warranty and limitation of liability
- Limited warranty and limitation of liabilit
- To register your product online visit register fluke com
- Title page
- Table of contents
- Table title page
- List of tables
- List of figures
- Figure title page
- Contacting fluke
- Introduction
- Insulation testers
- Xw warning
- Safety information
- Rotary switch positions
- Battery saver sleep mode
- Unsafe voltage
- Buttons and indicators
- Xw warning
- Understanding the display
- Cal err
- Power up options
- Input terminals
- Making measurements
- Xw warning
- Measuring volts
- Measuring earth bond resistance
- Measuring insulation resistance
- Measuring polarization index and dielectric absorption ratios model 1507
- Using the compare function model 1507
- Testing the batteries
- Cleaning
- Xw warning
- Testing the fuse
- Xw warning
- Replacing the batteries and fuse
- 1503 users manual
- Specifications
- General specifications
- V 0 v 2 3
- Range resolution 50 hz to 400 hz
- Of rdg digits
- Insulation testers specifications
- Accuracy
- Ac dc voltage measurement
- Insulation specifications
- Earth bond resistance measurement
- Model 1507
- Model 1503
- En61557 specification
- Insulation resistance maximum and minimum display values
- Insulation resistance maximum and minimum display values cont
- Insulation resistance maximum and minimum display values cont
- Insulation resistance maximum and minimum display values cont
- Earth bond resistance maximum display values
Похожие устройства
-
Fluke 568Инструкция к устройству -
Fluke 566Руководство пользователя -
Fluke 561Инструкция по применению -
Fluke 724Руководство по калибровке -
Fluke 724Паспорт безопасности -
Fluke 705Информация о калибровке -
Fluke 705Loop Calibrators Data Sheet -
Fluke 705Паспорт безопасности -
Fluke 705Приложение к паспорту безопасности -
Fluke 705Приложение к Инструкции -
Fluke 705Дополнение к информации о калибровке -
Fluke 707 exПриложение к Руководству по эксплуатации
Изучите функции индикаторов и сообщения об ошибках в пользовательском руководстве. Узнайте, как правильно использовать тестер и что означают различные индикаторы.