Insulation Testers
Cleaning
17
INSULATION TESTER
1507
bbw11f.eps
Figure 9. Using the Compare Function
Cleaning
Periodically wipe the case with a damp cloth and mild
detergent. Do not use abrasives or solvents. Dirt or
moisture in the terminals can affect readings. Allow time
for drying before using the Tester.
Testing the Batteries
The Tester continuously monitors battery voltage. If the
low battery icon (B) appears on the display, there is
minimal battery life left. To test the batteries:
1. Turn the rotary switch to the b position with no
probes inserted.
2. Press the blue button to initiate the fully loaded
battery test. The voltage function displays clear and
the measured battery voltage is shown in the primary
display for 2 seconds, the voltage display then
returns.
Содержание
58- 1503 insulation testers users manual
- Users manual
- Insulation testers
- Limited warranty and limitation of liability
- Limited warranty and limitation of liabilit
- To register your product online visit register fluke com
- Title page
- Table of contents
- Table title page
- List of tables
- List of figures
- Figure title page
- Contacting fluke
- Introduction
- Insulation testers
- Xw warning
- Safety information
- Rotary switch positions
- Battery saver sleep mode
- Unsafe voltage
- Buttons and indicators
- Xw warning
- Understanding the display
- Cal err
- Power up options
- Input terminals
- Making measurements
- Xw warning
- Measuring volts
- Measuring earth bond resistance
- Measuring insulation resistance
- Measuring polarization index and dielectric absorption ratios model 1507
- Using the compare function model 1507
- Testing the batteries
- Cleaning
- Xw warning
- Testing the fuse
- Xw warning
- Replacing the batteries and fuse
- 1503 users manual
- Specifications
- General specifications
- V 0 v 2 3
- Range resolution 50 hz to 400 hz
- Of rdg digits
- Insulation testers specifications
- Accuracy
- Ac dc voltage measurement
- Insulation specifications
- Earth bond resistance measurement
- Model 1507
- Model 1503
- En61557 specification
- Insulation resistance maximum and minimum display values
- Insulation resistance maximum and minimum display values cont
- Insulation resistance maximum and minimum display values cont
- Insulation resistance maximum and minimum display values cont
- Earth bond resistance maximum display values
Похожие устройства
-
Fluke 568Инструкция к устройству -
Fluke 566Руководство пользователя -
Fluke 561Инструкция по применению -
Fluke 724Руководство по калибровке -
Fluke 724Паспорт безопасности -
Fluke 705Информация о калибровке -
Fluke 705Loop Calibrators Data Sheet -
Fluke 705Паспорт безопасности -
Fluke 705Приложение к паспорту безопасности -
Fluke 705Приложение к Инструкции -
Fluke 705Дополнение к информации о калибровке -
Fluke 707 exПриложение к Руководству по эксплуатации
Узнайте, как правильно тестировать и обслуживать изоляторы. Советы по очистке, проверке батарей и поддержанию точности измерений.