the rating plate. The plug is to be inserted into a suitable
wall socket. If you require a direct connection to the elec-
tric network (mains), it will be necessary to fit between the
appliance and the mains an omnipole switch, with a mini-
mum gap between contacts of 3 mm, suitable for the re-
quired load and in compliance with rules in force. The
green & yellow ground wire must not be interrupted by the
switch, and should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases be laid
out in such a way as to ensure that it does not reach at any
given point a temperature 50°C higher than the ambient
temperature.
Applicable types of cables for Europe:
Minimum size Cable/flex: 1,5mm²
Cable/ flex type: H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F
Fuse 13 A
.
Applicable types of cables for UK only
Connection via Min. size Cable/flex Cable/flex type Fuse
13 A socket outlet
13 A spur box
2,5 mm² Three core butyl insulated 13 A min.
Oven Control Circuit 2,5 mm² PVC/PVC twin and earth 15 A min.
20 A min.
Terminal block
The oven is fitted with an easily accessible terminal block
which is designed to operate with a singlephase power
supply of 230 V.
Letter L Live terminal
Letter N Neutral terminal
or E
Earth terminal
The Manufacturer disclaims any liability in case these ac-
cident-preventing rules are not observed.
Instructions for Building In
For problem-free functioning of the built-in appliance, the
kitchen unit or the recess into which the appliance is built
must have suitable dimensions.
In accordance with the regulations in force, all parts which
ensure the shock protection of live and insulated parts
must be fastened in such a way that they cannot be un-
done without tools.
These also include the fixing of any end walls at the be-
ginning or end of a line of built-in units.
The shock protection must in any case be ensured by the
building in of the appliance.
The appliance can be placed with its back or a side wall
against higher kitchen units, appliances or walls. Howev-
er, only other appliances or units of the same height as
the appliance can be placed against the other side wall.
Overall oven dimensions
594
2
20
570
590
540
560
The recess must have the dimensions shown in the pic-
ture below.
In column building-in
The recess must have the dimensions shown in the pic-
ture below.
20