Binks Raptor MXL432PU-T-ACG [22/24] Fx4 fluid pump assemblies troubleshooting

Binks Raptor MXL432PU-T-ACG [22/24] Fx4 fluid pump assemblies troubleshooting
77-2907-EU
page 22 of 24
FX4 FLUID PUMP ASSEMBLIES – TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Material in solvent cup
Worn or dirty upper packings.
Replace or clean upper packings as
necessary.
Pump does not stop on
the down stroke
Worn or dirty lower ball check.
Replace or clean the parts as necessary.
Pump does not stop on
the up stroke
Worn or dirty upper ball check.
Worn or dirty lower packings.
Replace or clean the parts as
necessary.
Pump runs erratically
Blocked material siphon kit.
Blocked inlet filter or strainer.
Low material level.
Replace or clean the siphon kit.
Replace or clean inlet filter or strainer.
Replace or refill material container.
Pump runs, with no output
Loose connection in between
pump and siphon assembly.
Stuck lower ball.
Check that all connections are tight.
Replace or clean the parts as necessary.
FX4 МАТЕРИАЛЬНАЯ СЕКЦИЯ НАСОСА - УСТРАНЕНИЕ НЕИСПРАВНОСТЕЙ
ПРОБЛЕМЫ
ПРИЧИНЫ
РЕШЕНИЯ
МАТЕРИАЛ В ЕМКОСТИ ДЛЯ
СМАЗКИ
ИЗНОШЕНО ВЕРХНЕЕ УПЛОТНЕНИЕ
ЗАМЕНИТЕ ВЕРХНЕЕ УПЛОТНЕНИЕ
НАСОС НЕ ОСТАНАВЛИВАЕТСЯ В
НИЖНЕМ ПОЛОЖЕНИИ ПОРШНЯ
ПОЧИСТИТЕ ИЛИ ЗАМЕНИТЕ
НАСОС НЕ ОСТАНАВЛИВАЕТСЯ В
ВЕРХНЕМ ПОЛОЖЕНИИ ПОРШНЯ
ИЗНОШЕН ИЛИ ЗАГРЯЗНЕН ВЕРХНИЙ
ШАРИК
ИЗНОШЕНО ИЛИ ЗАГРЯЗНЕНО НИЖНЕЕ
УПЛОТНЕНИЕ
ПОЧИСТИТЕ ИЛИ ЗАМЕНИТЕ
НАСОС ЗАПУСТИЛСЯ И
РАБОТАЕТ ПРЕРЫВИСТО
ЗАБИТ ЗАБОРНЫЙ СИФОН
ЗАБИТ ВХОДЯЩИЙ ФИЛЬТР
НИЗКИЙ УРОВЕНЬ МАТЕРИАЛА
ПОЧИСТИТЕ ИЛИ ЗАМЕНИТЕ ЗАБОРНЫЙ СИФОН
ПОЧИСТИТЕ ИЛИ ЗАМЕНИТЕ ВХОДЯЩИЙ ФИЛЬТР
ЗАЛЕЙТЕ МАТЕРИАЛ
НАСОС ЗАПУСТИЛСЯ , НО НЕ КАЧАЕТ
НЕТ ПОДКЛЮЧЕНИЯ НАСОСА К ЗАБОРНОМУ
СИФОНУ
ПРИСОХ НИЖНИЙ ШАРИК
ПРОВЕРЬТЕ, ЧТОБЫ ВСЕ СОЕДИНЕНИЯ БЫЛИ
ПРОЧНО ПРИСОЕДИНЕНЫ
ПОЧИСТИТЕ ИЛИ ЗАМЕНИТЕ

Содержание

Скачать