Yaskawa CIMR-UU4A0240A [526/644] Automatically calculated energy saving coefficient kt value kt auto cal val

Yaskawa CIMR-UU4A0361F [526/644] Automatically calculated energy saving coefficient kt value kt auto cal val
No.
(Addr.
Hex)
Name LCD Display Description
Analog
Output Level
Unit
U5-05
(07D2)
PID Differential
Feedback
PID Feedback 2
All Modes
Displays the 2nd PID feedback value if differential feedback is
used (H3-oo = 16).
10 V: 100%
(-10 to +10 V)
0.01%
U5-06
(07D3)
PID Adjusted Feedback PID Diff Fdbk
All Modes
Displays the difference of both feedback values if differential
feedback is used (U5-01 - U5-05). If differential feedback is not
used, then U5-01 and U5-06 will be the same.
10 V: 100%
(-10 to +10 V)
0.01%
U5-21
(0872)
Automatically
Calculated Energy
Saving Coefficient Ki
Value
Ki Auto Cal Val
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM CLV/PMOLV/PM AOLV/PM CLV/PM
V/fOLV/PM
Displays the energy saving coefficient Ki value.
No signal output
available
0.01
U5-22
(0873)
Automatically
Calculated Energy
Saving Coefficient Kt
Value
Kt Auto Cal Val
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM CLV/PMOLV/PM AOLV/PM CLV/PM
V/fOLV/PM
Displays the energy saving coefficient Kt value.
No signal output
available
0.01
u
U6: Operation Status Monitors
No.
(Addr.
Hex)
Name LCD Display Description
Analog
Output Level
Unit
U6-01
(0051)
Motor Secondary
Current (Iq)
Mot SEC Current
All Modes
Displays the value of the motor secondary current (Iq). Motor
rated secondary current is 100%.
10 V: Motor
secondary rated
current
(-10 to +10 V)
0.1%
U6-02
(0052)
Motor Excitation
Current (Id)
Mot EXC Current
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM
OLV
CLV/PM
CLV
Displays the value calculated for the motor excitation current
(Id). Motor rated secondary current is 100%.
10 V: Motor
secondary rated
current
(-10 to +10 V)
0.1%
U6-03
(0054)
ASR Input ASR Input
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
CLV/PM
CLVV/f w PG
AOLV/PM
V/f w PG
AOLV/PM
Displays the input and output values when using ASR control.
10 V: Max
frequency
(-10 to +10 V)
0.01%
U6-04
(0055)
ASR Output ASR Output
10 V: Motor
secondary rated
current
(-10 to +10 V)
U6-05
(0059)
Output Voltage
Reference (Vq)
Voltage Ref (Vq)
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM
OLV
CLV/PM
CLV
Output voltage reference (Vq) for the q-Axis.
10 V: 200 Vrms
(-10 to +10 V)
<1>
0.1 Vac
U6-06
(005A)
Output Voltage
Reference (Vd)
Voltage Ref (Vd)
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM
OLV
CLV/PM
CLV
Output voltage reference (Vd) for the d-Axis.
10 V: 200 Vrms
(-10 to +10 V)
<1>
0.1 Vac
U6-07
(005F)
q-Axis ACR Output ACR(q) Output
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
OLV
CLV/PM
CLV
Displays the output value for current control relative to motor
secondary current (q-Axis).
10 V: 200 Vrms
(-10 to +10 V)
<1>
0.1%
U6-08
(0060)
d-Axis ACR Output ACR(d) Output
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
OLV
CLV/PM
CLV
Displays the output value for current control relative to motor
secondary current (d-Axis).
110 V: 200 Vrms
(-10 to +10 V)
<1>
0.1%
U6-09
(07C0)
Advance Phase
Compensation (
Δθ)
d-q Axis Comp
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
Displays the degree of forward phase correction after calculating
the deviation of Δθcmp.
10 V: 180 deg
-10 V: -180 deg
(-10 to +10 V)
0.1 deg
U6-10
(07C1)
Control Axis Deviation
(Δθ)
d-q Axis Devt
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
Displays the amount of deviation between the actual d-Axis / q-
Axis and the γ-Axis / δ-Axis used for motor control.
10 V: 180 deg
-10 V: -180 deg
(-10 to +10 V)
0.1 deg
B.15 U: Monitors
526
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual

Содержание

Похожие устройства

Скачать