Ridgid 37428 [8/427] Standard equipment

Ridgid 37428 [8/427] Standard equipment
micro CM-100 Digital Clamp Meter
6
Capacitance (Autoranging)
Frequency (Autoranging)
Sensitivity .....................................>5 V RMS minimum
Temperature
Diode Test
Open Circuit Voltage .....................1.5 V DC
Audible Continuity
Audible Threshold .........................< 35 Ω
Test Current ..................................< 1.0 mA
Standard Equipment
The RIDGID
®
micro CM-100 Digital Clamp Meter comes with the following items:
micro CM-100 Digital Clamp Meter
Test Leads with Covers, Black and Red
K Type Adapter and Temperature Probe
Figure 1 – micro CM-100 Digital Clamp Meter
Figure 2 – Back of micro CM-100 Digital Clamp Meter
Range Resolution Accuracy
4 ηF 0.001 ηF ±5.0% of Reading ± 30 Digits
40 ηF 0.01 ηF ±5.0% of Reading ± 20 Digits
400 ηF 0.1 ηF
4 µF 0.001 µF ±3.0% of Reading ± 5 Digits
40 µF 0.01 µF
400 µF 0.1 µF ±4.0% of Reading ± 10 Digits
4 mF 0.001 mF ±4.5% of Reading ± 10 Digits
40 mF 0.01 mF ±5.0% of Reading ± 10 Digits
Range Resolution Accuracy
4 kHz 0.001 kHz ±1.5% of Reading ± 2 Digits
Range Resolution Accuracy
-40°C to +1000°C 1°C ±2.5% of Reading ± 3°C
-40°F to +1832°F 1°F ±2.5% of Reading ± 5°F
Range Resolution Accuracy
0.3 mA Typical 1 mV ±10% of Reading ± 5 Digits
User Manual and Instruction CD
Carrying Case
Warning