Daikin FXAQ20MAVET Сервис мануал онлайн [258/264] 543605

Daikin FXAQ40MAVE Сервис мануал онлайн [258/264] 543602
SiBE34-703 RXYSQ4 · 5 · 6 P7Y1B
Removal Procedure 247
Step
Procedure Points
Make sure that there is no
refrigerant gas left within
the refrigerant circuit
system before performing
the operation
The cutting part is in the
compressor side relative to
the brazing part.
Preliminarily cut off with a
gas welder, a part of the
piping from the end side to
the soldered portion, which
have remained after being
cut using a pipe cutter,
before replacing with a new
compressor.
7
Cut off the suction pipe,
discharge pipe and
unloader pipe of
compressor with a pipe
cutter (three places).
Suction
pipe portion
Compressor
Unloader
piping portion
Discharge pipe portion
Warning
Refrigerant oil in the compressor
may catch fire, so prepare wet
cloth so as to extinguish a fire
rapidly.
Warning
If refrigerant gas leaks during
operation, ventilate the room.
(The exposure of refrigerant gas
to a fire causes generates toxic
gas.)
Caution
Do not suffer burns due to
contact with piping etc. heated by
a gas welder.