Daikin RXYQ32PY1 [27/38] Heat pump

Daikin RXYQ32PY1 [27/38] Heat pump
5251
OUTDOOR UNITSOUTDOOR UNITS
Standard models (Space Saving Types)
Refrigerant oil
Refer to the nameplate of the compressor
19.1 (Brazing)
34.9 (Brazing)
65
19.1 (Brazing)
41.3 (Brazing)
66
19.1 (Brazing)
41.3 (Brazing)
65
19.1 (Brazing)
41.3 (Brazing)
64
19.1 (Brazing)
41.3 (Brazing)
65
19.1 (Brazing)
41.3 (Brazing)
67
Power supply
3 phase, 380415 V, 50 Hz, 4 wires system
R410A
Cooling capacity
Btu/h(*1)
(*1)
kW
(*2)
kcal/h(*1)
Refrigerant
Motor output kW
((1.4+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
(3.8
X
1)+((2.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
(3.8
X
1)+((1.4+4.5+4.5)
X
1)+
((1.4+4.5+4.5)
X
1)
(3.8
X
1)+((1.4+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
(3.8
X
1)+((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
Refrigerant charge kg
Refrigerant oil charge
Machine weight kg
dB(A)
Capacity control
Heating capacity (*3)
Compressor
Sound level (*4)
%
kW
Btu/h
kcal/h
Air flow rate
Casing colour
Piping connections
Liquid pipe mm
Gas pipe mm
81,400
323,000
85,100
338,000
91,200
362,000
97,200
386,000
101,000
399,000
104,000
413,000
92,000
365,000
97,200
386,000
102,000
406,000
108,000
427,000
114,000
450,000
119,000
471,000
Hermetically sealed scroll type
12.5+12.7 12.7+12.7 7.7+10.0+12.7 7.7+12.5+12.5 7.7+12.5+12.7 7.7+12.7+12.7
329
+
341
341
+
341 205
+
285
+
341 205
+
329
+
329 205
+
329
+
341 205
+
341+341
107
94.6
(1,680
X
1,240
X
765)
+
(1,680
X
1,240
X
765)
113
99.0
119
106
(1,680
X
930
X
765)
+
(1,680
X
1,240
X
765)
+
(1,680
X
1,240
X
765)
125
113
132
117
138
121
94.0 98.0 105 112 116 120
Dimensions(H
X
W
X
D)
mm
MODEL
Constituent Units
RXYQ16PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ8PY1(E)
RXYQ12PY1(E)
RXYQ18PY1(E)
RXYQ8PY1(E)
RXYQ16PY1(E)
RXYQ16PY1(E)
RXYQ34PY1(E) RXYQ36PY1(E) RXYQ38PY1(E) RXYQ40PY1(E) RXYQ42PY1(E) RXYQ44PY1(E)
RXYQ8PY1(E)
RXYQ16PY1(E)
RXYQ18PY1(E)
RXYQ8PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
Without (E): Ivory white (5Y7.5/1), With (E): Light camel (2.5Y6.5/1.5)
5-100 4-100 4-100 4-100 4-100 4-100
Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of
the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a
result of ambient conditions.
Use C1220T-1/2H for over 19.1
3. Total refrigerant volume should be 100 kg or less.
Refrigerant oil
Refer to the nameplate of the compressor
19.1 (Brazing)
41.3 (Brazing)
67
19.1 (Brazing)
41.3 (Brazing)
67
19.1 (Brazing)
41.3 (Brazing)
67
19.1 (Brazing)
41.3 (Brazing)
67
19.1 (Brazing)
41.3 (Brazing)
68
Power supply
3 phase, 380415 V, 50 Hz, 4 wires system
R410A
Cooling capacity
Btu/h(*1)
(*1)
kW
(*2)
kcal/h(*1)
Refrigerant
Motor output kW
((1.2+4.5)
X
1)+((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
(1,680
X
930
X
765)+(1,680
X
1,240
X
765)+(1,680
X
1,240
X
765)
((2.5+4.5)
X
1)+((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
((0.3+4.5+4.5)
X
1)+((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
((1.4+4.5+4.5)
X
1)+((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
((3.0+4.5+4.5)
X
1)+((3.0+4.5+4.5)
X
1)+
((3.0+4.5+4.5)
X
1)
Refrigerant charge kg
Refrigerant oil charge
Machine weight kg
dB(A)
Capacity control
Heating capacity (*3)
Compressor
Sound level (*4)
%
kW
Btu/h
kcal/h
Air flow rate
Casing colour
Piping connections
Liquid pipe mm
Gas pipe mm
109,000
433,000
114,000
454,000
120,000
474,000
124,000
491,000
127,000
505,000
125,000
495,000
130,000
515,000
136,000
539,000
140,000
556,000
146,000
580,000
Hermetically sealed scroll type
8.4+12.7+12.7 10.0+12.7+12.7 12.3+12.7+12.7 12.5+12.7+12.7 12.7+12.7+12.7
249
+
341
+
341 285
+
341
+
341 329
+
341
+
341 329
+
341
+
341 341
+
341
+
341
145
127
(1,680
X
1,240
X
765)
+
(1,680
X
1,240
X
765)
+
(1,680
X
1,240
X
765)
151
133
158
139
163
144
170
148
126 132 138 143 147
Dimensions(H
X
W
X
D)
mm
MODEL
Constituent Units
RXYQ10PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ12PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ14PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ16PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ46PY1(E) RXYQ48PY1(E) RXYQ50PY1(E) RXYQ52PY1(E) RXYQ54PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
RXYQ18PY1(E)
Without (E): Ivory white (5Y7.5/1), With (E): Light camel (2.5Y6.5/1.5)
3-100 3-100 3-100 3-100 3-100
Note : 1. Models with (E) feature components treated for heat and rust corrosion
resistance, such as external panels, fan motor, and electric component box, in addition
to the fins of the heat exchanger. These models are designed specifically for use in
areas which are subject to salt damage and atmospheric pollution.Please contact
Daikin for more information.
2. Specifications are based on the following conditions;
•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.
(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Heating : (*3) Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
•(*1)(*2)(*3) Equivalent piping length : 7.5 m, level difference 0 m.
Specifications
Heat Pump
Standard models (Space Saving Types)
Refrigerant oil
Refrigerant
Motor output kW
Refrigerant charge kg
Refrigerant oil charge
Machine weight kg
dB(A)
Dimensions(H
X
W
X
D)
mm
Capacity control
Heating capacity (*3)
Cooling capacity
Btu/h(*1)
Compressor
Sound level (*4)
(*1)
%
kW
Btu/h
kcal/h
kW
(*2)
Air flow rate
Power supply
Casing colour
R410A
2.8
X
1 3.8
X
1 (1.2
+
4.5)
X
1
6.2
7.7 8.4
160 205 249
54 57 58
1,680
X
635
X
765 1,680
X
930
X
765
285
60
28-100 20-100 14-100
9.5 (Brazing)
15.9 (Brazing)
9.5 (Brazing)
19.1 (Brazing)
9.5 (Brazing)
22.2 (Brazing)
16.0
54,600
13,800
25.0
85,300
21,500
31.5
107,000
27,100
14.1
48,100
12,100
22.5
76,800
19,400
28.2
96,200
24,300
Hermetically sealed scroll type
(0.3
+
4.5
+
4.5)
X
1
329
60
14.0 22.4 28.0
14-100
37.5
128,000
32,300
33.7
115,000
29,000
33.5
10-100
45.0
154,000
38,700
40.2
137,000
34,600
40.0
10.0
12.7 (Brazing)
28.6 (Brazing)
12.3
12.7 (Brazing)
28.6 (Brazing)
Without (E): Ivory white (5Y7.5/1), With (E): Light camel (2.5Y6.5/1.5)
3 phase, 380415 V, 50 Hz, 4 wires system
(2.5
+
4.5)
X
1
1,680
X
1,240
X
765
329
60
10-100
50.0
171,000
43,000
45.3
155,000
39,000
45.0
12.5
12.7 (Brazing)
28.6 (Brazing)
(1.4
+
4.5
+
4.5)
X
1
341
63
RXYQ5PY1(E) RXYQ8PY1(E) RXYQ10PY1(E) RXYQ12PY1(E) RXYQ14PY1(E) RXYQ16PY1(E) RXYQ18PY1(E)
9-100
56.5
193,000
48,600
49.3
168,000
42,400
49.0
12.7
15.9 (Brazing)
28.6 (Brazing)
(3.0
+
4.5
+
4.5)
X
1
MODEL
kcal/h(*1)
Piping connections
Liquid pipe mm
Gas pipe mm
90.5
MODEL
Constituent Units
RXYQ20PY1(E) RXYQ22PY1(E)
RXYQ8PY1(E)
RXYQ12PY1(E)
RXYQ10PY1(E)
RXYQ12PY1(E)
19.1 (Brazing)
34.9 (Brazing)
63
329
+
329
100
(1,680
X
930
X
765)
+
(1,680
X
1,240
X
765)
RXYQ24PY1(E) RXYQ26PY1(E)
RXYQ8PY1(E)
RXYQ16PY1(E)
RXYQ8PY1(E)
RXYQ18PY1(E)
RXYQ28PY1(E) RXYQ30PY1(E)
RXYQ10PY1(E)
RXYQ18PY1(E)
RXYQ12PY1(E)
RXYQ18PY1(E)
RXYQ32PY1(E)
RXYQ16PY1(E)
RXYQ16PY1(E)
5-100
90.0
Power supply
3 phase, 380415 V, 50 Hz, 4 wires system
R410A
Cooling capacity
Btu/h(*1)
(*1)
kW
(*2)
kcal/h(*1)
Refrigerant
Motor output kW
((1.4
+
4.5
+
4.5)
X
1)
+
((1.4
+
4.5
+
4.5)
X
1)
Refrigerant charge kg
Refrigerant oil charge
Machine weight kg
dB(A)
Dimensions(H
X
W
X
D)
mm
Capacity control
Heating capacity (*3)
Compressor
Sound level (*4)
%
kW
Btu/h
kcal/h
Air flow rate
Casing colour
Piping connections
Liquid pipe mm
Gas pipe mm
77,800
309,000
86,000
341,000
Hermetically sealed scroll type
Without (E): Ivory white (5Y7.5/1), With (E): Light camel (2.5Y6.5/1.5)
12.5
+
12.5
15.9 (Brazing)
28.6 (Brazing)
62
205
+
285
62.5
56.2
15.9 (Brazing)
28.6 (Brazing)
62
249
+
285
69.0
61.9
15.9 (Brazing)
34.9 (Brazing)
62
205
+
329
75.0
67.8
19.1 (Brazing)
34.9 (Brazing)
64
205
+
341
81.5
71.8
19.1 (Brazing)
34.9 (Brazing)
64
249
+
341
88.0
77.5
19.1 (Brazing)
34.9 (Brazing)
65
285
+
341
94.0
83.0
(1,680
X
1,240
X
765)
+
(1,680
X
1,240
X
765)
8-100 7-100
6-100
6-100 5-100 5-100
55.9 61.5 67.4 71.4 77.0 82.5
(3.8
X
1)
+
((2.5
+
4.5)
X
1)
((1.2
+
4.5)
X
1)
+
((2.5
+
4.5)
X
1)
(3.8
X
1)
+
((1.4
+
4.5
+
4.5)
X
1)
(3.8
X
1)
+
((3.0
+
4.5
+
4.5)
X
1)
((1.2
+
4.5)
X
1)
+
((3.0
+
4.5
+
4.5)
X
1)
((2.5
+
4.5)
X
1)
+
((3.0
+
4.5
+
4.5)
X
1)
48,300
192,000
53,200
211,000
58,300
231,000
61,700
250,000
66,700
264,000
71,400
283,000
53,800
213,000
59,300
235,000
64,500
256,000
70,100
278,000
75,700
300,000
80,800
321,000
7.7
+
10.0 8.4
+
10.0 7.7
+
12.5 7.7
+
12.7 8.4
+
12.7 10.0
+
12.7
Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of
the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a
result of ambient conditions.
Use C1220T-1/2H for over 19.1
3. Total refrigerant volume should be 100 kg or less.
Refer to the nameplate of the compressor
Refrigerant oil
Refer to the nameplate of the compressor
Note : 1. Models with (E) feature components treated for heat and rust corrosion
resistance, such as external panels, fan motor, and electric component box, in addition
to the fins of the heat exchanger. These models are designed specifically for use in
areas which are subject to salt damage and atmospheric pollution. Please contact
Daikin for more information.
2. Specifications are based on the following conditions;
•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.
(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Heating : (*3) Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
•(*1)(*2)(*3) Equivalent piping length : 7.5m, level difference 0m.
/s 1,583 3,000 3,083 3,883 3,883 3,883 3,983
/s 3,883
+
3,8833,000
+
3,883 3,083
+
3,883 3,000
+
3,883 3,000
+
3,983 3,083
+
3,983 3,883
+
3,983
/s 3,883+3,983 3,983+3,983 3,000+3,883+3,983 3,000+3,883+3,883 3,000+3,883+3,983 3,000+3,983+3,983
/s 3,083+3,983+3,983 3,883+3,983+3,983 3,883+3,983+3,983 3,883+3,983+3,983 3,983+3,983+3,983
m
3
/min 95 180 185 233 233 233 239
m
3
/min 233
+
233180
+
233 185
+
233 180
+
233 180
+
239 185
+
239 233
+
239
m
3
/min 233+239 239+239 180+233+239 180+233+233 180+233+239 180+239+239
m
3
/min 185+239+239 233+239+239 233+239+239 233+239+239 239+239+239

Содержание