Daikin RXYQ32PY1 [8/38] Main features

Daikin RXQ52PY1 [8/38] Main features
A sense of responsibility Enhanced comfort
Main Features
1413
Outdoor units designed for low-noise operation
High COPs
It has become essential for air conditioning manufacturers to develop systems that
provide high energy savings. We at Daikin have made great efforts in this field, and
the newly-developed VRVIII delivers highly efficient performance, contributing to high
energy savings.
Outdoor units created with cutting-edge technologies provide quiet operation to
increase users’ comfort.
Efficient compressor
New high-performance, low-noise scroll compressor operates at a
faster rate, reducing start-up time. This helps the unit to bring the
room temperature up to the set level quickly.
Nighttime quiet operation function
Compliant with the RoHS Directive*
We have been making efforts to facilitate the transition to using RoHS Directive*-compliant
materials for system parts.
Less chances of refrigerant leakage
Conventionally, shutoff valve connections are flanged or flared. In the VRVIII system, the connections for all
outdoor units are brazed, meaning less chance of refrigerant leakage.
* RoHS Directive
The RoHS (Restriction of Hazardous Substances (in electrical and electronic equipment))
Directive is an environmental directive enacted to regulate the use of designated chemical
substances (lead, cadmium, hexavalent chromium, mercury, polybrominated biphenyls and
polybrominated diphenylether) in electrical equipment. All household products subject to
this Directive and sold in Europe from July 1, 2006 are legally bound to comply with the
RoHS Directive.
Set on the outdoor PCB. Time of maximum
temperature is memorised. The low
operating mode will initiate 8 hours
*2
after
the peak temperature in the daytime, and
normal operation will resume 10 hours
*3
after
that. The operation sound level for the night
mode can be selected from 55 dB (Step 1),
50 dB (Step 2) and 45 dB (Step 3).
(For a single outdoor unit.)
Automatic mode
Operation sound level selectable from 3 steps for the night mode
Mode 1.
Automatic mode
Mode 1.
Starting time and ending time can be input.
(External control adaptor for outdoor unit,
DTA104A61 or DTA104A62, and a field
supplied time clock are necessary.)
Manual mode
Mode 2.
Combination of mode 1 and 2 can be used
depending on your needs.
Combined mode
Mode 3.
*1. Determine which mode to select depending on the
climatic characteristics of each country.
*2. Initial setting. Can be selected from 6, 8 and 10 hours.
*3. Initial setting. Can be selected from 8, 9 and 10 hours.
• This function is available in setting at site.
• The relationship of outdoor temperature (load) and time shown in the
graph is just an example.
Improved
New
New
We have reached a new level of
efficiency, thanks to the new advanced
features such as the heat exchanger,
the grille and the dual DC fans.
Achieving a higher COP
•Cooling operating conditions: Indoor temp. of 27
°C
DB, 19.0
°C
WB, and outdoor temp. of 35
°C
DB.
•Heating operating conditions: Indoor temp. of 20
°C
DB, and outdoor temp. of 7
°C
DB, 6
°C
WB.
1
16 class (45 kW)
VRVII
MA series
24 class (67.4 kW)
2
3
4
3.52
4.31
3.75
4.32
Comparison of VRVII and VRVIII
Standard models
(Space saving types)
High efficiency types
(Energy saving types)
(Average values of cooling and heating operations)
Approx.31%
*
increase
!
* Compared to VRV II MA series
3.30
3.56
The capacity reduction rate differs depending on the operation sound level step selected.
Note:
Improved
Improved
Improved
Peak in the outdoor temperature (For 10 class, 28 kW outdoor unit)
Capacity %
8 hrs 10 hrs
Operation sound dB
50
8:00 12:00 16:00 20:00 0:00 4:00 8:00
50
100
58
55
0
Load %
Night mode endsNight mode starts Night mode endsNight mode starts
Night Mode
45
(Initial setting)(Initial setting)
Step 2 max. - 8dB
Step 1 max. - 3dB
Step 3 max. - 13dB
Step 2: 50 dB
Step 1: 55 dB
Step 3: 45 dB